No Benefit of Patient-specific Instrumentation in TKA on Functional and Gait Outcomes: A Randomized Clinical Trial

被引:75
作者
Abdel, Matthew P. [1 ]
Parratte, Sebastien [2 ,3 ]
Blanc, Guillaume [2 ]
Ollivier, Matthieu [2 ]
Pomero, Vincent [3 ]
Viehweger, Elke [3 ]
Argenson, Jean-Noel A. [2 ,3 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
[2] Aix Marseille Univ, Inst Locomot, Dept Orthoped Surg, F-13274 Marseille, France
[3] Timone Hosp, Dept Pediat Orthopaed Surg, Ctr Mot & Gait Anal, Marseille, France
关键词
TOTAL KNEE ARTHROPLASTY; ROTATIONAL ALIGNMENT; COMPONENT ROTATION; PATELLAR TRACKING; WALKING; NAVIGATION; ACCURACY; POSITION;
D O I
10.1007/s11999-014-3544-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Although some clinical reports suggest patient-specific instrumentation in TKA may improve alignment, reduce surgical time, and lower hospital costs, it is unknown whether it improves pain- and function-related outcomes and gait. We hypothesized that TKA performed with patient-specific instrumentation would improve patient-reported outcomes measured by validated scoring tools and level gait as ascertained with three-dimensional (3-D) analysis compared with conventional instrumentation 3 months after surgery. We randomized 40 patients into two groups using either patient-specific instrumentation or conventional instrumentation. Patients were evaluated preoperatively and 3 months after surgery. Assessment tools included subjective functional outcome and quality-of-life (QOL) scores using validated questionnaires (New Knee Society Score(A (c)) [KSS], Knee Injury and Osteoarthritis Outcome Score [KOOS], and SF-12). In addition, gait analysis was evaluated with a 3-D system during level walking. The study was powered a priori at 90% to detect a difference in walking speed of 0.1 m/second, which was considered a clinically important difference, and in a post hoc analysis at 80% to detect a difference of 10 points in KSS. There were improvements from preoperatively to 3 months postoperatively in functional scores, QOL, and knee kinematic and kinetic gait parameters during level walking. However, there was no difference between the patient-specific instrumentation and conventional instrumentation groups in KSS, KOOS, SF-12, or 3-D gait parameters. Our observations suggest that patient-specific instrumentation does not confer a substantial advantage in early functional or gait outcomes after TKA. It is possible that differences may emerge, and this study does not allow one to predict any additional variances in the intermediate followup period from 6 months to 1 year postoperatively. However, the goals of the study were to investigate the recovery period as early pain and functional outcomes are becoming increasingly important to patients and surgeons. Level I, therapeutic study. See the Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:2468 / 2476
页数:9
相关论文
共 66 条
[1]
Rotational Position of Femoral and Tibial Components in TKA Using the Femoral Transepicondylar Axis [J].
Aglietti, Paolo ;
Sensi, Lorenzo ;
Cuomo, Pierluigi ;
Ciardullo, Antonio .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (11) :2751-2755
[2]
Ahlbck S., 1968, Acta Radiol Diagn (Stockh), P7
[3]
Akagi M, 1999, CLIN ORTHOP RELAT R, P155
[4]
Variability of extraarticular tibial rotation references for total knee arthroplasty [J].
Akagi, M ;
Mori, S ;
Nishimura, S ;
Nishimura, A ;
Asano, T ;
Hamanishi, C .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :172-176
[5]
Gait after Unilateral Total Knee Arthroplasty: Frontal Plane Analysis [J].
Alnahdi, Ali H. ;
Zeni, Joseph A. ;
Snyder-Mackler, Lynn .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (05) :647-652
[6]
ANOUCHI YS, 1993, CLIN ORTHOP RELAT R, P170
[7]
Patient-reported Outcome Correlates With Knee Function After a Single-design Mobile-bearing TKA [J].
Argenson, Jean-Noel ;
Parratte, Sebastien ;
Ashour, Abdullah ;
Komistek, Richard D. ;
Scuderi, Giles R. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (11) :2669-2676
[8]
The Outcome of Rotating-Platform Total Knee Arthroplasty with Cement at a Minimum of Ten Years of Follow-up [J].
Argenson, Jean-Noel A. ;
Parratte, Sebastien ;
Ashour, Abdullah ;
Saintmard, Bertrand ;
Aubaniac, Jean-Manuel .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (07) :638-644
[9]
Minimally invasive total knee arthroplasty [J].
Argenson, JN ;
Parratte, S ;
Flecher, X .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2005, 91 :28-30
[10]
Ast Michael P, 2012, Orthop Clin North Am, V43, pe17, DOI 10.1016/j.ocl.2012.07.004