Analysis of the short-term overproduction capability of variable speed wind turbines

被引:60
作者
Hansen, Anca D. [1 ]
Altin, Mufit [1 ]
Margaris, Ioannis D. [2 ]
Iov, Florin [3 ]
Tarnowski, German C. [4 ]
机构
[1] Tech Univ Denmark, Dept Wind Energy, Odense, Denmark
[2] Natl Tech Univ Athens, GR-10682 Athens, Greece
[3] Aalborg Univ, Dept Energy Technol, Aalborg, Denmark
[4] Natl Univ Misiones, Ctr Energy Studies Dev, Posadas, Argentina
关键词
Active power; Overproduction; Inertial response; Variable speed wind turbine; Standard model; FREQUENCY CONTROL;
D O I
10.1016/j.renene.2014.02.012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Emphasis in this article is on variable speed wind turbines (VSWTs) capability to provide short-term overproduction and better understanding of VSWTs' mechanical and electrical limits to deliver such support. VSWTs' short-term overproduction capability is of primary concern for the transmission system operators (TSOs) in the process of restoring critical situations during large frequency excursions in power systems with high wind power penetration. This study is conducted on a simplified generic model for VSWTs with full scale power converter (Type IV), which includes several adjustments and extensions of the Type IV standard wind turbine model proposed by the IEC Committee in IEC 61400-27-1. This modified standard model is able to account for dynamic features relevant for integrating active power ancillary services in wind power plants, such as frequency support capabilities. The performance of VSWTs during short-term overproduction is assessed and discussed by means of simulations for different wind speed levels, overproduction percentages and durations. The results show that the capability of VSWTs providing short-term overproduction to the grid strongly depends on the initial pre-overproduction conditions. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:326 / 336
页数:11
相关论文
共 17 条
  • [1] [Anonymous], 2011, REN UK PO PAP IN V3
  • [2] [Anonymous], 8 INT WORKSH LARG SC
  • [3] [Anonymous], 2012, 6140027 IEC
  • [4] [Anonymous], 2012, P C WIRELESS HLTH SA, DOI DOI 10.1145/2448096.2448097
  • [5] Christensen P. W., 2011, 10 INT WORKSH LARG S
  • [6] Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency
    Ekanayake, J
    Jenkins, N
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (04) : 800 - 802
  • [7] Gowaid I.A., 2011, IEEE POW EN SOC GEN
  • [8] Hansen AD, 2013, SIMPLIFIED TYPE 4 WI
  • [9] Co-ordinated voltage control of DFIG wind turbines in uninterrupted operation during grid faults
    Hansen, Anca D.
    Michalke, Gabriele
    Sorensen, Poul
    Lund, Torsten
    Iov, Florin
    [J]. WIND ENERGY, 2007, 10 (01) : 51 - 68
  • [10] Frequency control and wind turbine technologies
    Lalor, G
    Mullane, A
    O'Malley, M
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (04) : 1905 - 1913