Synthetic pyrethroid insecticides in fish: Analysis by gas chromatography mass spectrometry operated in the negative ion chemical ionization mode and ELISA

被引:14
作者
Bonwick, GA
Yasin, M
Hancock, P
Baugh, PJ
Williams, JHH
Smith, CJ
Armitage, R
Davies, DH
机构
[1] CORTECS DIAGNOST,DEESIDE CH5 2NT,CLWYD,WALES
[2] NATL RIVERS AUTHOR,YORKSHIRE & NORTHUMBRIA REG,LEEDS LS1 2QP,W YORKSHIRE,ENGLAND
[3] UNIV SALFORD,DEPT SCI BIOL,MANCHESTER M5 4WT,LANCS,ENGLAND
[4] UNIV SALFORD,DEPT CHEM & APPL CHEM,SALFORD M5 4WT,GREATER MANCHES,ENGLAND
[5] UNIV SALFORD,DEPT BIOL SCI,SALFORD M5 4WT,GREATER MANCHES,ENGLAND
关键词
pyrethroids; fish; immunoassay; gas chromatography mass spectrometry;
D O I
10.1080/09540109609354916
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Brown trout (Salmo trutta) were captured from a headwater stream contaminated with moth-proofing agents. Synthetic pyrethroid residues within the tissues were obtained by ultrasonic extraction and examined by gas chromatography-mass spectrometry operated in the negative ion chemical ionization mode (GC/NCI-MS). Both permethrin and cyfluthrin had been bioaccumulated by the fish and the mean concentrations (+/- standard deviation) recorded were 2046 (+/-203) mu g kg(-1) and 25.4 (+/-46.9) mu g kg(-1) respectively. The concentrations of these pyrethroids are the highest recorded for freshwater fish captured from a natural ecosystem. At the time of sampling, permethrin could be detected within the stream water (0.034 mu g l(-1)) while cyfluthrin could not. A mean relative bioconcentration factor of approximately 60 000 was derived for the brown trout which was also greater than any previously determined for freshwater fish The fish tissue extracts were also analyzed through use of an ELISA for permethrin. The ELISA reported consistently lower concentrations than those obtained by GC/NCI-MS. This was attributed to analyte losses during preparation of the sample extracts in a form suitable for incorporation into the ELISA. The concentrations obtained by ELISA were significantly correlated with those obtained by GC/NCI-MS (R(2) = 0.985, n = 5). Overall, the ELISA appeared to be suitable for the detection of permethrin in fish when present at concentrations in excess of the maximum residue level suggested for many foods by the Commission of the European Economic Community.
引用
收藏
页码:185 / 194
页数:10
相关论文
共 18 条
  • [1] Bonwick G. A., 1994, Food and Agricultural Immunology, V6, P341, DOI 10.1080/09540109409354847
  • [2] Bonwick G. A., 1994, Food and Agricultural Immunology, V6, P267, DOI 10.1080/09540109409354838
  • [3] DETERMINATION OF PERMETHRIN AND CYFLUTHRIN IN WATER AND SEDIMENT BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY OPERATED IN THE NEGATIVE CHEMICAL-IONIZATION MODE
    BONWICK, GA
    SUN, C
    ABDULLATIF, P
    BAUGH, PJ
    SMITH, CJ
    ARMITAGE, R
    DAVIES, DH
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 707 (02) : 293 - 302
  • [4] HAMMOCK BD, 1986, PESTICIDE SCI BIOTEC
  • [5] NRCC (National Research Council of Canada), 1986, NRCC PUBL
  • [6] FATE OF PERMETHRIN IN MODEL OUTDOOR PONDS
    RAWN, GP
    WEBSTER, GRB
    MUIR, DCG
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 1982, 17 (05) : 463 - 486
  • [7] RAWN GP, 1980, 15 ANN WORKSH PEST R, P25
  • [8] RAWN GP, 1980, CANADIAN TECHNICAL R, V975, P140
  • [9] ADSORPTION-DESORPTION, DEGRADATION, AND DISTRIBUTION OF PERMETHRIN IN AQUEOUS SYSTEMS
    SHAROM, MS
    SOLOMON, KR
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1981, 29 (06) : 1122 - 1125
  • [10] SMITH C, 1992, PYRETHROID PESTICIDE