Study on a dual-mode, multi-stage, multi-bed regenerative adsorption chiller

被引:61
作者
Saha, Bidyut B.
Koyama, Shigeru
Ng, Kim Choon
Hamamoto, Yoshinori
Akisawa, Atsushi
Kashiwagi, Takao
机构
[1] Kyushu Univ, Inst Mat Chem & Engn, Kasuga, Fukuoka 8168580, Japan
[2] Natl Univ Singapore, Dept Mech Engn, Singapore 119260, Singapore
[3] Tokyo Univ Agr & Technol, Bio Applicat & Syst Engn, Koganei, Tokyo 1848588, Japan
关键词
adsorption; dual-mode; multi-bed; parametric study; silica gel-water; solar energy utilization;
D O I
10.1016/j.renene.2005.10.003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, a detailed parametric study on a dual-mode silica gel-water adsorption chiller is performed. This advanced adsorption chiller utilizes effectively low-temperature solar or waste heat sources of temperature between 40 and 95 degrees C. Two operation modes are possible for the advanced chiller. The first operation mode will be to work as a highly efficient conventional chiller where the driving source temperature is between 60 and 95 degrees C. The second operation mode will be to work as an advanced three-stage adsorption chiller where the available driving source temperature is very low (between 40 and 60 degrees C). With this very low driving source temperature in combination with a coolant at 30 degrees C, no other cycle except an advanced adsorption cycle with staged regeneration will be operational. In this paper, the effect of chilled-water inlet temperature, heat transfer fluid flow rates and adsorption-desorption cycle time effect on cooling capacity and COP of the dual-mode chiller is performed. Simulation results show that both cooling capacity and COP values increase with the increase of chilled water inlet temperature with driving source temperature at 50 and 80 degrees C in three-stage mode, and single-stage multi-bed mode, respectively. However, the delivered chilled-water temperature increases with chilled-water inlet temperature in both modes. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2076 / 2090
页数:15
相关论文
共 9 条
[1]   Forced convection adsorption cycle with packed bed heat regeneration [J].
Critoph, RE .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (01) :38-46
[2]   EXPERIMENTAL-STUDY OF CASCADING ADSORPTION CYCLES [J].
DOUSS, N ;
MEUNIER, F .
CHEMICAL ENGINEERING SCIENCE, 1989, 44 (02) :225-235
[3]   ANALYTICAL MODEL FOR THE THERMAL WAVE ADSORPTION HEAT-PUMP CYCLE [J].
HARKONEN, M ;
AITTOMAKI, A .
HEAT RECOVERY SYSTEMS & CHP, 1992, 12 (01) :73-80
[4]   THEORETICAL PERFORMANCES OF SOLID ADSORBENT CASCADING CYCLES USING THE ZEOLITE WATER AND ACTIVE-CARBON METHANOL PAIRS - 4 CASE-STUDIES [J].
MEUNIER, F .
JOURNAL OF HEAT RECOVERY SYSTEMS, 1986, 6 (06) :491-498
[5]   Waste heat driven dual-mode, multi-stage, multi-bed regenerative adsorption system [J].
Saha, BB ;
Koyama, S ;
Kashiwagi, T ;
Akisawa, A ;
Ng, KC ;
Chua, HT .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (07) :749-757
[6]  
Saha BB, 1995, ASHRAE TRAN, V101, P348
[7]  
SAHA BB, 1997, THESIS TOKYO U AGR T
[8]   FUNDAMENTAL-STUDY ON SOLAR POWERED ADSORPTION COOLING SYSTEM [J].
SAKODA, A ;
SUZUKI, M .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1984, 17 (01) :52-57
[9]  
SHELTON SV, 1989, HEAT RECOVER SYSTEMS, V9, P223