Early results of the Minns meniscal bearing total knee prosthesis

被引:68
作者
Shaw, NJ
Minns, RJ
Epstein, HP
Sutton, RA
机构
[1] DRYBURN HOSP,DURHAM DH1 5TW,ENGLAND
[2] HEXHAM GEN HOSP,NORTHUMBERLAND,ENGLAND
关键词
Minns meniscal bearing; total knee replacement; post-operative motion;
D O I
10.1016/S0968-0160(97)00264-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The preliminary results of the Minns meniscal bearing total knee replacement are presented with an average follow-up of 62.5 months (range 38-78 months). A total of 90 cemented meniscal bearing total replacements of this design were performed on 67 consecutive patients. Three died of unrelated causes and four failed to attend for follow-up investigation. Consequently, 80 knees in 60 patients were reviewed with an average follow-up time of 62.5 months. Using the American Knee Society scoring system (see Appendix 1), 82% rated good or excellent, 11% were rated fair and 6% poor. There was a clinical improvement in all cases except one patient and pain relief was achieved in most cases (96%). Five knees had some mild pain on activity post-operatively. The average range of motion post-operatively was 98 degrees and there were no cases of dislocation of the polyethylene bearings. There was a single case of radiological loosening which subsequently proved to be an infected prosthesis requiring revision surgery. Survivorship analysis (Kaplain-Meier survival curve) shows that 98.9% of the knees survived at five years follow-up. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:185 / 191
页数:7
相关论文
共 23 条
[1]  
ARGENSON JN, 1992, J BONE JT SURG BR B, V74, P28
[2]  
BARTEL DL, 1986, J BONE JT SURG AM A, V68, P1043
[3]  
BERT JM, 1990, CLIN ORTHOP RELAT R, V254, P211
[4]  
BEUCHEL FF, 1994, J ORTHOP RHEUMATOL, V71, P31
[5]   THE NEW-JERSEY LOW-CONTACT-STRESS KNEE REPLACEMENT SYSTEM - BIOMECHANICAL RATIONALE AND REVIEW OF THE 1ST 123 CEMENTED CASES [J].
BUECHEL, FF ;
PAPPAS, MJ .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1986, 105 (04) :197-204
[6]   USE OF A TOTAL CONDYLAR KNEE PROSTHESIS FOR TREATMENT OF OSTEO-ARTHRITIS AND RHEUMATOID-ARTHRITIS - LONG-TERM RESULTS [J].
GOLDBERG, VM ;
FIGGIE, MP ;
FIGGIE, HE ;
HEIPLE, KG ;
SOBEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (06) :802-811
[7]   MECHANICS OF KNEE AND PROSTHESIS DESIGN [J].
GOODFELLOW, J ;
OCONNOR, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1978, 60 (03) :358-369
[8]  
INSALL JN, 1976, J BONE JT SURG AM A, V61, P173
[9]  
Keblish P, 1991, Acta Orthop Belg, V57 Suppl 2, P124
[10]   The 'sliding meniscus' knee prosthesis: Design concepts [J].
Minns, R.J. ;
Campbell, J. .
Engineering in Medicine, 1979, 8 (04) :201-205