Restricted posterior leaflet motion after mitral ring annuloplasty

被引:102
作者
Green, GR
Dagum, P
Glasson, JR
Nistal, JF
Daughters, GT
Ingels, NB
Miller, DC [1 ]
机构
[1] Stanford Univ, Sch Med, Falk Cardiovasc Res Ctr, Dept Cardiovasc & Thorac Surg, Stanford, CA 94305 USA
[2] Univ Santander, Santander, Spain
[3] Palo Alto Med Fdn, Res Inst, Dept Cardiovasc Physiol & Biophys, Palo Alto, CA 94301 USA
关键词
D O I
10.1016/S0003-4975(99)01175-3
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background. The effects of ring annuloplasty on mitral leaflet motion are incompletely known. The three-dimensional dynamics of the mitral valve in vivo were examined to determine how two types of annuloplasty rings affect leaflet motion during valve closure. Methods. Miniature radiopaque markers on the mitral leaflets, annulus, and left ventricle were implanted in three groups of sheep. One group served as control (n = 7); other sheep were randomly assigned to receive either a flexible Duran (n = 6) or a semirigid Carpentier-Edwards Physio ring (n = 6). After recovery, three-dimensional marker coordinates were computed from simultaneous (60 Hz) biplane videofluoroscopic marker images. Results. Both types of rings immobilized the middle scallop of the posterior leaflet without affecting anterior leaflet motion. The excursion of the anterior leaflet edge from maximally open to fully closed was not different between the groups (control, 13 +/- 2 mm; Duran 13 +/- 1 mm; Physio ring, 14 +/- 1 mm; p > 0.05), but posterior leaflet edge excursion was restricted (control, 7.4 +/- 0.4 mm; 2.3 +/- 0.3 mm [p < 0.001]; Physio, 2.7 +/- 0.2 mm [p < 0.001]) by both rings. Conclusions, Mitral annuloplasty with either ring type markedly reduced the mobility of the central posterior leaflet in normal ovine hearts such that valve closure became essentially a single (anterior) leaflet process with the frozen posterior leaflet serving only as a buttress for closing. (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:2100 / 2106
页数:7
相关论文
共 20 条
[1]
CARPENTIER A, 1971, J THORAC CARDIOV SUR, V61, P1
[2]
THE PHYSIO-RING - AN ADVANCED CONCEPT IN MITRAL-VALVE ANNULOPLASTY [J].
CARPENTIER, AF ;
LESSANA, A ;
RELLAND, JYM ;
BELLI, E ;
MIHAILEANU, S ;
BERREBI, AJ ;
PALSKY, E ;
LOULMET, DF .
ANNALS OF THORACIC SURGERY, 1995, 60 (05) :1177-1186
[3]
COHN LH, 1994, J THORAC CARDIOV SUR, V107, P143
[4]
DAUGHTERS GT, 1988, P COMP CARDIOL IEEE, V15, P79
[5]
DIASTOLIC LOCKING OF THE MITRAL-VALVE - THE IMPORTANCE OF ATRIAL SYSTOLE AND INTRAVENTRICULAR VOLUME [J].
DAVID, D ;
MICHELSON, EL ;
NAITO, M ;
CHEN, CC ;
SCHAFFENBURG, M ;
DREIFUS, LS .
CIRCULATION, 1983, 67 (03) :640-645
[6]
MITRAL-VALVE ANNULOPLASTY - THE EFFECT OF THE TYPE ON LEFT-VENTRICULAR FUNCTION [J].
DAVID, TE ;
KOMEDA, M ;
POLLICK, C ;
BURNS, RJ .
ANNALS OF THORACIC SURGERY, 1989, 47 (04) :524-528
[7]
CLINICAL AND HEMODYNAMIC PERFORMANCE OF A TOTALLY FLEXIBLE PROSTHETIC RING FOR ATRIOVENTRICULAR VALVE RECONSTRUCTION [J].
DURAN, CG ;
UBAGO, JLM .
ANNALS OF THORACIC SURGERY, 1976, 22 (05) :458-463
[8]
Durability of mitral valve repair for degenerative disease [J].
Gillinov, AM ;
Cosgrove, DM ;
Blackstone, EH ;
Diaz, R ;
Arnold, JH ;
Lytle, BW ;
Smedira, NG ;
Sabik, JF ;
McCarthy, PM ;
Loop, FD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (05) :734-742
[9]
GLASSON JR, 1997, CIRCULATION S1, V96, P684
[10]
LINEARITY OF THE FRANK-STARLING RELATIONSHIP IN THE INTACT HEART - THE CONCEPT OF PRELOAD RECRUITABLE STROKE WORK [J].
GLOWER, DD ;
SPRATT, JA ;
SNOW, ND ;
KABAS, JS ;
DAVIS, JW ;
OLSEN, CO ;
TYSON, GS ;
SABISTON, DC ;
RANKIN, JS .
CIRCULATION, 1985, 71 (05) :994-1009