Conformations of biopolymers in the gas phase: a new mass spectrometric method

被引:51
作者
Gill, AC
Jennings, KR
Wyttenbach, T
Bowers, MT [1 ]
机构
[1] Univ Calif Santa Barbara, Dept Chem, Santa Barbara, CA 93106 USA
[2] Univ Warwick, Dept Biol Sci, Coventry CV4 7AL, W Midlands, England
基金
美国国家科学基金会; 英国工程与自然科学研究理事会;
关键词
biopolymers; gas phase; mass spectrometry; collision cross sections;
D O I
10.1016/S1387-3806(99)00256-0
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A method is developed for measuring collision cross sections of gas-phase biomolecules using a slightly modified commercial triple quadrupole instrument. The modifications allow accurate stopping potentials to be measured for ions exiting the collision region of the instrument. A simple model allows these curves to be converted to cross sections. In order to account for certain poorly defined experimental parameters (exact ion energy, absolute pressure in the collision cell, etc.) variable parameters are included in the model. These parameters are determined on a case by case basis by normalizing the results to the well known cross section of singly charged bradykinin, Two relatively large systems were studied (cytochrome c and myoglobin) so comparisons could be made to literature values. A number of new peptide systems were then studied in the 9 -14 residue range. These included singly and doubly charged ions of luteinizing hormone releasing hormone (LHRH) substance P, and bombesin in addition to bradykinin. The experimental cross sections were in very good agreement with predictions from extensive molecular dynamics modeling. One interesting result was the experimental observation that the cross section of the doubly charged ions of LHRH, substance P, and bombesin were all smaller than those of the corresponding singly charged ions. Molecular dynamics did not reproduce this result, predicting doubly charged cross sections of the same magnitude or slightly larger than for the singly charged species. The experimental results appear to be correct, however. Possible shortcomings in the modeling procedure for multiply charged ions were suggested that might account for the discrepancy. (C) 2000 Elsevier Science B.V.
引用
收藏
页码:685 / 697
页数:13
相关论文
共 31 条
[1]  
BATKA J, UNPUB
[2]  
Blundell T. L., 1976, Protein crystallography
[4]   HIGH-RESOLUTION 3-DIMENSIONAL STRUCTURE OF HORSE HEART CYTOCHROME-C [J].
BUSHNELL, GW ;
LOUIE, GV ;
BRAYER, GD .
JOURNAL OF MOLECULAR BIOLOGY, 1990, 214 (02) :585-595
[5]   Collision cross sections of myoglobin and cytochrome c ions with Ne, Ar, and Kr [J].
Chen, YL ;
Collings, BA ;
Douglas, DJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (07) :681-687
[6]   HYDROGEN-DEUTERIUM EXCHANGE OF MASS-SELECTED PEPTIDE IONS WITH ND3 IN A TANDEM SECTOR MASS-SPECTROMETER [J].
CHENG, XH ;
FENSELAU, C .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 122 :109-119
[7]  
Clemmer DE, 1997, J MASS SPECTROM, V32, P577
[8]   High-order structure and dissociation of gaseous peptide aggregates that are hidden in mass spectra [J].
Counterman, AE ;
Valentine, SJ ;
Srebalus, CA ;
Henderson, SC ;
Hoaglund, CS ;
Clemmer, DE .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (08) :743-759
[9]   COLLISION CROSS-SECTIONS FOR PROTEIN IONS [J].
COVEY, T ;
DOUGLAS, DJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (08) :616-623
[10]   CONFORMER SELECTION OF PROTEIN IONS BY ION MOBILITY IN A TRIPLE QUADRUPOLE MASS-SPECTROMETER [J].
COX, KA ;
JULIAN, RK ;
COOKS, RG ;
KAISER, RE .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (03) :127-136