Sedimentation velocity analytical ultracentrifugation and SEDFIT/c(s):: Limits of quantitation for a monoclonal antibody system

被引:43
作者
Gabrielson, John P.
Randolph, Theodore W.
Kendrick, Brent S.
Stoner, Michael R. [1 ]
机构
[1] Amgen Inc, Longmont, CO 80503 USA
[2] Univ Colorado, Dept Chem & Biol Engn, Boulder, CO 80309 USA
关键词
analytical ultracentrifugation; sedimentation velocity; SEDFIT; monoclonal antibody; limit of quantitation;
D O I
10.1016/j.ab.2006.11.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sedimentation velocity analytical ultracentrifugation (SV-AUC) has emerged in the biopharmaceutical industry as a technique to detect small quantities of protein aggregates. However, the limits of detection and quantitation of these aggregates are not yet well understood. Although diverse factors (molecule, instrument, technique, and software dependent) preclude an all-encompassing measurement of these limits for the complete system, it is possible to use simulated data to determine the quantitation limits of the data analysis software aspect. The current study examines the performance of the SEDFIT/c(s) data analysis tool with simulated antibody monomer/dimer and monomer/aggregate systems. Under completely ideal conditions (zero noise, known meniscus, and shape factor homogeneity), the software limit of quantitation was 0.01% for the monomer/aggregate system and 0.03% for the less well-resolved monomer/dimer system. Under more realistic conditions (0.005 OD root mean square [RMS] noise, shape factor variability, and long solution column), the software limits of quantitation were 0.2 and 0.6% (0.002 and 0.006 OD) for the monomer/aggregate and monomer/dimer systems, respectively. Interestingly, diminished quantitation accuracy at very low levels of oligomer was not accompanied by deterioration of fit quality (as measured by root mean square deviation [RMSD] and residuals bitmap images). (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 18 条
[1]   Analysis of aggregates of human immunoglobulin G using size-exclusion chromatography, static and dynamic light scattering [J].
Ahrer, K ;
Buchacher, A ;
Iberer, G ;
Josic, D ;
Jungbauer, A .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1009 (1-2) :89-96
[2]  
ARMBRUSTER DA, 1994, CLIN CHEM, V40, P1233
[3]  
CANTOR CR, 1980, BIOPHYSICAL CHEM 2
[4]  
Dam J, 2004, METHOD ENZYMOL, V384, P185
[5]   HYDRODYNAMIC PROPERTIES OF COMPLEX, RIGID, BIOLOGICAL MACROMOLECULES - THEORY AND APPLICATIONS [J].
DELATORRE, JG ;
BLOOMFIELD, VA .
QUARTERLY REVIEWS OF BIOPHYSICS, 1981, 14 (01) :81-139
[6]  
Demeler B, 2005, ANALYTICAL ULTRACENTRIFUGATION: TECHNIQUES AND METHODS, P210
[7]  
Fujita H, 1962, MATH THEORY SEDIMENT
[8]   Structure-immunogenicity relationships of therapeutic proteins [J].
Hermeling, S ;
Crommelin, DJA ;
Schellekens, H ;
Jiskoot, W .
PHARMACEUTICAL RESEARCH, 2004, 21 (06) :897-903
[9]  
Lamm O., 1929, ARK MAT ASTRON FYS, V21, P1
[10]  
Laue T. M., 1992, Analytical Ultracentrifugation in Biochemistry and Polymer Science, DOI [10.1016/0169-2607(96)01719-1, DOI 10.1016/0169-2607(96)01719-1]