The results of total arch graft implantation with open stent-graft placement for type A aortic dissection

被引:93
作者
Kato, M
Kuratani, T
Kaneko, M
Kyo, S
Ohnishi, K
机构
[1] Saitama Med Sch, Div Thorac & Cardiovasc Surg, Dept Surg, Moroyama, Saitama 3500495, Japan
[2] Osaka Prefecture Hosp, Div Cardiovasc Surg, Osaka, Japan
关键词
D O I
10.1067/mtc.2002.124388
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: One problem that conventional ascending treatment for type A aortic dissection has not satisfactorily resolved is chronic enlargement of residual dissection in the aortic arch and descending aorta. To address this problem, we have developed a new method for type A aortic dissection: total arch graft implantation with open-style stent-graft placement. Methods: From October 1994 through October 1999, 19 patients with type A aortic dissection (13 acute and 6 chronic dissections) underwent total arch graft implantation with open-style stent-graft placement. After achievement of general anesthesia and hypothermic extracorporeal circulation, we replaced the dissected ascending aorta and neck vessels with a 4-branched graft and repaired the descending aorta with a stent graft to close the entry site completely and to obtain better peripheral perfusion. We then examined the acute-phase and chronic-phase results and the outcomes of the false lumen and dissected aorta. Results: There were 1 (5.3%) hospital death and 2 late deaths. The survivals at 1 and 3 years were 89.5% and 82.6%, respectively. The following complications occurred in the perioperative period: 1 stroke, 2 cases of temporary paraparesis, 2 cases of temporary hemodialysis, and 3 cases of mediastinitis. No pulmonary complications were observed. Six months postoperatively, the targeted entry sites were completely closed in all cases, 80% (8/10) of preoperatively patent false lumina were clotted at the level of the end of the stent graft, and 60% (9/15) of the false lumina and 40% (6/15) of the dissected aorta had shrunk significantly. Two (13.3%) of 15 cases of postoperative dilatation in the dissected aorta were observed, and reoperation related to residual dissected aorta was performed in only 1 (1/17 [5.9%]) patient during the mean follow-up period of 2.4 +/- 1.6 years. Conclusion: Our preliminary review of the total arch graft implantation with a stent graft suggests that this new procedure for type A aortic dissection might provide better results in both the acute and the chronic phase, especially with regard to the outcome for the false lumen and dissected aorta.
引用
收藏
页码:531 / 540
页数:10
相关论文
共 34 条
[1]   SIMULTANEOUS GRAFT REPLACEMENT OF THE ASCENDING AORTA AND TOTAL AORTIC-ARCH FOR TYPE-A AORTIC DISSECTION [J].
ANDO, M ;
NAKAJIMA, N ;
ADACHI, S ;
NAKAYA, M ;
KAWASHIMA, Y .
ANNALS OF THORACIC SURGERY, 1994, 57 (03) :669-676
[2]  
BACHET J, 1988, J THORAC CARDIOV SUR, V96, P878
[3]  
BACHET J, 1990, J CARDIOVASC SURG, V31, P263
[4]  
BACHET JE, 1994, J THORAC CARDIOV SUR, V108, P199
[5]  
Borst H G, 1987, Eur J Cardiothorac Surg, V1, P186, DOI 10.1016/1010-7940(87)90040-6
[6]  
CACHERA JP, 1981, J THORAC CARDIOV SUR, V82, P576
[7]   AORTIC DISSECTION AND DISSECTING AORTIC-ANEURYSMS [J].
CRAWFORD, ES ;
SVENSSON, LG ;
COSELLI, JS ;
SAFI, HJ ;
HESS, KR .
ANNALS OF SURGERY, 1988, 208 (03) :254-273
[8]  
CRAWFORD ES, 1992, J THORAC CARDIOV SUR, V104, P46
[9]   Endovascular stent-graft placement for the treatment of acute aortic dissection [J].
Dake, MD ;
Kato, N ;
Mitchell, RS ;
Semba, CP ;
Razavi, MK ;
Shimono, T ;
Hirano, T ;
Takeda, K ;
Yada, I ;
Miller, DC .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (20) :1546-1552
[10]   The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta [J].
Dake, MD ;
Miller, DC ;
Mitchell, RS ;
Semba, CP ;
Moore, KA ;
Sakai, T .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (05) :689-703