Highly sensitive time-resolved fluorometric determination of estrogens by high-performance liquid chromatography using a β-diketonate europium chelate

被引:23
作者
Matsumoto, K [1 ]
Tsukahara, Y
Uemura, T
Tsunoda, K
Kume, H
Kawasaki, S
Tadano, J
Matsuya, T
机构
[1] Waseda Univ, Dept Chem, Adv Res Ctr Sci & Engn, Shinjuku Ku, Tokyo 1698555, Japan
[2] Gunma Univ, Sch Engn, Dept Appl Chem, Gunma 3760052, Japan
[3] Hamamatsu Phonton KK, R&D Dev, Electron Tube Div, Shizuoka 4380193, Japan
[4] Saga Med Sch Hosp, Dept Lab Med, Saga 8498501, Japan
[5] Iatron Labs Inc, Res Labs, Div Res & Dev, Chiba 2892247, Japan
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 773卷 / 02期
关键词
derivatization; LC; estrogens; beta-diketonate europium;
D O I
10.1016/S1570-0232(02)00137-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new fluorescent europium chelate labeling reagent, 5-(4"-chlorosulfo-1',1"-diphenyl-4'-yl)-1,1,1,2,2-pentafluoro-3,5-pentanedione (CDPP), was synthesized for the time-resolved fluorometric detection of HPLC. The label can be directly bound to amino or phenolic hydroxyl groups of analytes with its chlorosulfonyl group, and the labeled analytes are separated on a HPLC column. After separation, EuCl3, TOPO (tri-n-octylphosphine oxide), and Triton X-100 were added by post-column introduction to the eluent, and the fluorescence of the europium chelate was measured with the time-resolved fluorometric detector. Estrone (E1), 17beta-estradiol (E2), ethynylestradiol (EE2) and estriol (E3) were measured with the detection limits of 0.65, 0.65, 0.65 and 0.60 ng/ml, respectively. The recovery for river water samples was in the range of 86.0-105.1% with the RSD of 1.9-5.8%. The method was applied to the analysis of a river water sample and estrone (E1) was determined to be 2.1 ng/l. The results and processing have been compared with those of a GC-MS method and a high degree of correlation (rgreater than or equal to0.98) was observed. (C) 2002 Elsevier Science B.V. All lights reserved.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 25 条
[1]   DETERMINATION OF STEROIDS IN URINE BY MICELLAR HPLC WITH DETECTION BY SENSITIZED TERBIUM FLUORESCENCE [J].
AMIN, M ;
HARRINGTON, K ;
VONWANDRUSZKA, R .
ANALYTICAL CHEMISTRY, 1993, 65 (17) :2346-2351
[2]  
DIAMANDIS EP, 1988, CLIN BIOCHEM, V21, P139, DOI 10.1016/0009-9120(88)90001-X
[3]   EUROPIUM CHELATE LABELS IN TIME-RESOLVED FLUORESCENCE IMMUNOASSAYS AND DNA HYBRIDIZATION ASSAYS [J].
DIAMANDIS, EP ;
CHRISTOPOULOS, TK .
ANALYTICAL CHEMISTRY, 1990, 62 (22) :A1149-+
[4]  
DICKSON EFG, 1995, PHARMACOL THERAPEUT, V66, P207
[5]   UNIDIMENSIONAL CHROMATOGRAPHIC SEPARATION OF DANSYL CATECHOLAMINES [J].
DILIBERTO, EJ ;
DISTEFANO, V .
ANALYTICAL BIOCHEMISTRY, 1969, 32 (02) :281-+
[6]   The lanthanides as luminescent probes in investigations of biochemical systems [J].
Elbanowski, M ;
Makowsaka, B .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 1996, 99 (2-3) :85-92
[7]   Simultaneous determination of anabolic and catabolic steroid hormones in meat by gas chromatography mass spectrometry [J].
Hartmann, S ;
Steinhart, H .
JOURNAL OF CHROMATOGRAPHY B, 1997, 704 (1-2) :105-117
[9]   LUMINESCENT LANTHANIDE CHELATES - A WAY TO MORE SENSITIVE DIAGNOSTIC METHODS [J].
HEMMILA, I .
JOURNAL OF ALLOYS AND COMPOUNDS, 1995, 225 (1-2) :480-485
[10]  
HEMMILA I, 1985, CLIN CHEM, V31, P359