An ex vivo method for evaluating the biocompatibility of neural electrodes in rat brain slice cultures

被引:12
作者
Koeneman, BA
Lee, KK
Singh, A
He, JP
Raupp, GB
Panitch, A [1 ]
Capco, DG
机构
[1] Arizona State Univ, Sch Life Sci, Cellular & Mol Biosci Fac, Tempe, AZ 85287 USA
[2] Arizona State Univ, Harrington Dept Bioengn, Tempe, AZ 85287 USA
[3] Arizona State Univ, Dept Chem & Mat Engn, Tempe, AZ 85287 USA
[4] Arizona State Univ, Arizona BioDesign Inst, Tempe, AZ 85287 USA
基金
美国国家科学基金会;
关键词
biocompatibility; brain slice culture; glial cells; neural electrode; neurons; polybenzocyclobutene (BCB);
D O I
10.1016/j.jneumeth.2004.02.033
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Failure of neural recording electrodes implanted in the brain is often attributed to the formation of glial scars around the implant. A leading cause of sear formation is the electrode material. Described below is an approach to evaluate the biocompatibility of novel electrode materials in a representative three-dimensional model. The model, brain slice culture, accounts for the response of the neural tissue in the absence of the systemic response. While limitations of any in vitro model exist, brain slice culture provides an indication of the response of neurons and glia in an environment more indicative of the in vivo environment than two-dimensional cell culture of glia or neurons alone. Polybenzylcyclobutene (BCB) electrodes were developed as test materials for flexible electrodes due to ease of processing, low water uptake, and inherent flexibility when formed in thin sheets. Biocompatibilty of the BCB neural electrodes was evaluated using living brain slices derived from the hippocampal regions of 100 g CD rats. Importantly, fewer animals can be used in brain slice culture to evaluate the neural tissue response than when using live animals, since several slices can be obtained per animal. Cellular response to the electrodes was evaluated at 0, 7, and 14 days. At all time points living cells, both neurons and glia, were observed in the vicinity of the electrode. In addition, cells were observed migrating out from the brain slices onto the shank of the BCB electrode. Brain slice culture is shown to be a viable alternative to in vivo evaluation, in that the response of both neurons and glia can be evaluated in a native three-dimensional state, while sacrificing fewer animals. Future in vivo evaluation with BCB will provide definitive answers on the degree of glial scarring in response to this new and biocompatible electrode material. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:257 / 263
页数:7
相关论文
共 14 条
[1]   OPTIMIZED SURVIVAL OF HIPPOCAMPAL-NEURONS IN B27-SUPPLEMENTED NEUROBASAL(TM), A NEW SERUM-FREE MEDIUM COMBINATION [J].
BREWER, GJ ;
TORRICELLI, JR ;
EVEGE, EK ;
PRICE, PJ .
JOURNAL OF NEUROSCIENCE RESEARCH, 1993, 35 (05) :567-576
[2]   A metallic multisite recording system designed for continuous long-term monitoring of electrophysiological activity in slice cultures [J].
Duport, S ;
Millerin, C ;
Muller, D ;
Corrèges, P .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (04) :369-376
[3]   A novel organotypic long-term culture of the rat hippocampus on substrate-integrated multielectrode arrays [J].
Egert, U ;
Schlosshauer, B ;
Fennrich, S ;
Nisch, W ;
Fejtl, M ;
Knott, T ;
Muller, T ;
Hammerle, H .
BRAIN RESEARCH PROTOCOLS, 1998, 2 (04) :229-242
[4]   Glial cell and fibroblast cytotoxicity study on 4026-cyclotene photosensitive benzocyclobutene (BCB) polymer films [J].
Ehteshami, G ;
Singh, A ;
Coryell, G ;
Massia, S ;
He, JP ;
Raupp, G .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2003, 14 (10) :1105-1116
[5]   Organotypic slice cultures: a technique has come of age [J].
Gahwiler, BH ;
Capogna, M ;
Debanne, D ;
McKinney, RA ;
Thompson, SM .
TRENDS IN NEUROSCIENCES, 1997, 20 (10) :471-477
[6]   A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices [J].
Heuschkel, MO ;
Fejtl, M ;
Raggenbass, M ;
Bertrand, D ;
Renaud, P .
JOURNAL OF NEUROSCIENCE METHODS, 2002, 114 (02) :135-148
[7]   Coupling of organotypic brain slice cultures to silicon-based arrays of electrodes [J].
Jahnsen, H ;
Kristensen, BW ;
Thiébaud, P ;
Noraberg, J ;
Jakobsen, B ;
Bove, M ;
Martinoia, S ;
Koudelka-Hep, M ;
Grattarola, M ;
Zimmer, J .
METHODS-A COMPANION TO METHODS IN ENZYMOLOGY, 1999, 18 (02) :160-172
[8]   Biocompatibility of silicon-based arrays of electrodes coupled to organotypic hippocampal brain slice cultures [J].
Kristensen, BW ;
Noraberg, J ;
Thiébaud, P ;
Koudelka-Hep, M ;
Zimmer, J .
BRAIN RESEARCH, 2001, 896 (1-2) :1-17
[9]   Quantitative analysis of glioma cell invasion by confocal laser scanning microscopy in a novel brain slice model [J].
Matsumura, H ;
Ohnishi, T ;
Kanemura, Y ;
Maruno, M ;
Yoshimine, T .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2000, 269 (02) :513-520
[10]   Markers for neuronal degeneration in organotypic slice cultures [J].
Noraberg, J ;
Kristensen, BW ;
Zimmer, J .
BRAIN RESEARCH PROTOCOLS, 1999, 3 (03) :278-290