The effect of a soft collar, used as normally recommended or reversed, on three planes of cervical range of motion

被引:24
作者
Carter, VM
Fasen, JAM
Roman, JM
Hayes, KW
Petersen, CM
机构
[1] THERATX,DENVER,CO
[2] CTR SPINE SPORT & OCCUPAT REHABIL,CHICAGO,IL
[3] ST MARY NAZARETH,CHICAGO,IL
[4] NORTHWESTERN UNIV,SCH MED,PROGRAMS PHYS THERAPY,CHICAGO,IL
关键词
cervical; orthosis; range of motion;
D O I
10.2519/jospt.1996.23.3.209
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Clinicians recommend soft cervical collars to immobilize the cervical spine following trauma. They apply them either as intended by the manufacturer or reversed (collar rotated 180 degrees), purportedly to achieve limitation in a specific direction. This study investigated the effectiveness of soft cervical collars in limiting cervical range of motion when worn as recommended or reversed. All planes of cervical range of motion of 50 volunteer subjects without current or past cervical dysfunction were measured under three conditions (no collar, recommended use, and reversed) using the Orthopedic Systems Inc. Computerized Anatometry-6000 Spine Motion Analyzer. The instrument has been previously shown to produce measures with high reliability and to correlate strongly with known angular: measures. Within subjects analyses of variance indicated significant differences in all six ranges of motions among the three conditions. Post hoc paired t tests showed that wearing a collar either as recommended or reversed decreased motion compared with not wearing a collar, and that the position of the collar affected range of motion in three of the six motions. Differences in range can be attributed to location of the collar closure and initial head posture. Soft cervical collars can physically limit motion when worn either way.
引用
收藏
页码:209 / 215
页数:7
相关论文
共 24 条
[1]
CERVICAL COLLARS IN RHEUMATOID ATLANTO-AXIAL SUBLUXATION - A RADIOGRAPHIC COMPARISON [J].
ALTHOFF, B ;
GOLDIE, IF .
ANNALS OF THE RHEUMATIC DISEASES, 1980, 39 (05) :485-489
[2]
BEAVIS A, 1989, PROSTHET ORTHOT INT, V13, P6
[3]
RELIABILITY OF GONIOMETRIC MEASUREMENTS [J].
BOONE, DC ;
AZEN, SP ;
LIN, CM ;
SPENCE, C ;
BARON, C ;
LEE, L .
PHYSICAL THERAPY, 1978, 58 (11) :1355-1360
[4]
COLACHIS SC, 1973, ARCH PHYS MED REHAB, V54, P161
[5]
DUDGEON P, 1984, BR J OCCUP THER, V47, P247
[6]
CLINICAL MEASUREMENT OF RANGE OF MOTION - REVIEW OF GONIOMETRY EMPHASIZING RELIABILITY AND VALIDITY [J].
GAJDOSIK, RL ;
BOHANNON, RW .
PHYSICAL THERAPY, 1987, 67 (12) :1867-1872
[7]
GRIEVE GP, 1986, MODERN MANUAL THERAP, P77
[8]
REVIEW OF CERVICAL ORTHOSES [J].
HART, DL ;
JOHNSON, RM ;
SIMMONS, EF ;
OWEN, J .
PHYSICAL THERAPY, 1978, 58 (07) :857-860
[9]
HARTMAN JT, 1975, CLIN ORTHOP RELAT R, V109, P97
[10]
JOHNSON RD, 1993, PHYS THER, V72, pS108