Gait assessment in unicompartmental knee arthroplasty patients: Principal component modelling of gait waveforms and clinical status

被引:44
作者
Deluzio, KJ [1 ]
Wyss, UP
Costigan, PA
Sorbie, C
Zee, B
机构
[1] Kingston Gen Hosp, Apps Med Res Ctr, Clin Mech Grp, Kingston, ON K7L 2V7, Canada
[2] Queens Univ, Dept Mech Engn, Kingston, ON K7L 3N6, Canada
[3] Queens Univ, Sch Phys & Hlth Educ, Kingston, ON K7L 3N6, Canada
[4] Queens Univ, Dept Surg, Kingston, ON K7L 3N6, Canada
[5] Queens Univ, Natl Canc Inst Canada, Clin Trials Grp, Kingston, ON K7L 3N6, Canada
关键词
principal component analysis; statistics; gait analysis; knee kinematics and kinetics; osteoarthritis; unicompartmental knee replacement;
D O I
10.1016/S0167-9457(99)00030-5
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The reduction and analysis of gait waveform data is a significant barrier to the clinical application of gait analysis. Principal component modelling of gait waveform data reduced the waveform data to measures of distance from normal and these distance measures were shown to be sensitive to changes in gait pattern associated with knee osteoarthritis and its treatment by unicompartmental arthroplasty. Principal component models were developed for eight knee kinematic and kinetic gait waveforms of a group of 30 normal elderly subjects. Each model consisted of a set of loading vectors, principal component scores and residuals. The loading vectors revealed the structure of the model and the scores and residuals were used as the distance measures about which confidence intervals were developed. Pre-operative and post-operative gait data from 13 unicompartmental arthroplasty (UCA) patients were used to demonstrate the application of the principal component models to pathological gait data. A gait score was developed to indicate the overall assessment of the kinematic and kinetic gait measures by the principal component models. This gait score was shown to agree with the clinical status as measured by the Knee Society Score (pre-op: r(s) = 0.86; post-op: r(s) = 0.73) Thus, the differences in gait pattern detected by the principal component models were clinical relevant. (C) 1999 Elsevier Science B.V. All rights reserved. PsycINFO classification: 2330; 2240; 2380.
引用
收藏
页码:701 / 711
页数:11
相关论文
共 29 条
[1]   NORMATIVE DATA OF KNEE-JOINT MOTION AND GROUND REACTION FORCES IN ADULT LEVEL WALKING [J].
CHAO, EY ;
LAUGHMAN, RK ;
SCHNEIDER, E ;
STAUFFER, RN .
JOURNAL OF BIOMECHANICS, 1983, 16 (03) :219-233
[2]   Functional analysis of cemented medial unicompartmental knee arthroplasty [J].
Chassin, EP ;
Mikosz, RP ;
Andriacchi, TP ;
Rosenberg, AG .
JOURNAL OF ARTHROPLASTY, 1996, 11 (05) :553-559
[3]   SEMIAUTOMATIC 3-DIMENSIONAL KNEE MOTION ASSESSMENT SYSTEM [J].
COSTIGAN, PA ;
WYSS, UP ;
DELUZIO, KJ ;
LI, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (03) :343-350
[4]   Principal component models of knee kinematics and kinetics: Normal vs. pathological gait patterns [J].
Deluzio, KJ ;
Wyss, UP ;
Zee, B ;
Costigan, PA ;
Sorbie, C .
HUMAN MOVEMENT SCIENCE, 1997, 16 (2-3) :201-217
[5]   A PROCEDURE TO VALIDATE 3-DIMENSIONAL MOTION ASSESSMENT SYSTEMS [J].
DELUZIO, KJ ;
WYSS, UP ;
LI, JA ;
COSTIGAN, PA .
JOURNAL OF BIOMECHANICS, 1993, 26 (06) :753-759
[6]  
DIAS RC, 1992, THESIS QUEENS U KING
[7]   THE PREVALENCE OF KNEE OSTEOARTHRITIS IN THE ELDERLY - THE FRAMINGHAM OSTEOARTHRITIS STUDY [J].
FELSON, DT ;
NAIMARK, A ;
ANDERSON, J ;
KAZIS, L ;
CASTELLI, W ;
MEENAN, RF .
ARTHRITIS AND RHEUMATISM, 1987, 30 (08) :914-918
[8]  
GIOFTSOS G, 1993, USE NEURAL NETWORKS, P777
[9]   ASSESSMENT OF GAIT PATTERNS USING NEURAL NETWORKS [J].
HOLZREITER, SH ;
KOHLE, ME .
JOURNAL OF BIOMECHANICS, 1993, 26 (06) :645-651
[10]  
INSALL JN, 1989, CLIN ORTHOP RELAT R, P13