An oblique cylinder contrast-adjusted (OCCA) phantom to measure the accuracy of MRI brain lesion volume estimation schemes in multiple sclerosis

被引:22
作者
Tofts, PS
Barker, GJ
Filippi, M
GawneCain, M
Lai, M
机构
[1] Institute of Neurology, London WC1N 3BG, Queen Square
[2] Department of Neurology, Sci. Inst. Ospedale San Raffaele, University of Milan, Milan
关键词
multiple sclerosis; lesion volume; accuracy; precision; reproducibility; treatment trial; MRI;
D O I
10.1016/S0730-725X(96)00339-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new OCCA phantom using Oblique Cylinders and Contrast Adjustment for measuring the accuracy of brain lesion volume estimation schemes is described, It uses obliquely oriented cylinders made from acrylic rod, mounted in a water bath, to give realistic partial volume errors, Image intensities are inverted, scaled, and shifted, and noise is added, to form images that have realistic values of lesion-white matter contrast (5-30%) and contrast-to-noise ratio (3-20%), Artificial gray matter, CSF(cerebrospinal fluid), and scalp lipid are added because these bright areas may determine how the gray level display window is set, The performance of manual and contouring methods for estimating lesion volume was measured for three observers and nine lesions with individual volumes from 0.3 to 6.2 mi, There was a large variation, depending on the choice of method, the observer, and the lesion contrast. Volumes were usually overestimated, with the error increasing at high contrasts, The average error in estimating total lesion volume was 17% (range -16% to +36%), The OCCA phantom may have a role in training observers to improve their accuracy (and hence inter- and intraobserver reproducibility). (C) 1997 Elsevier Science Inc.
引用
收藏
页码:183 / 192
页数:10
相关论文
共 19 条
[1]  
DAVIES SEC, 1995, J NEUROCHEM, V64, P742
[2]   Quantitative assessment of MRI lesion load in monitoring the evolution of multiple sclerosis [J].
Filippi, M ;
Horsfield, MA ;
Tofts, PS ;
Barkhof, F ;
Thompson, AJ ;
Miller, DH .
BRAIN, 1995, 118 :1601-1612
[3]   Intra- and inter-observer agreement of brain MRI lesion volume measurements in multiple sclerosis - A comparison of techniques [J].
Filippi, M ;
Horsfield, MA ;
Bressi, S ;
Martinelli, V ;
Baratti, C ;
Reganati, P ;
Campi, A ;
Miller, DH ;
Comi, G .
BRAIN, 1995, 118 :1593-1600
[4]   RESOLUTION-DEPENDENT ESTIMATES OF LESION VOLUMES IN MAGNETIC-RESONANCE-IMAGING STUDIES OF THE BRAIN IN MULTIPLE-SCLEROSIS [J].
FILIPPI, M ;
HORSFIELD, MA ;
CAMPI, A ;
MAMMI, S ;
PEREIRA, C ;
COMI, G .
ANNALS OF NEUROLOGY, 1995, 38 (05) :749-754
[5]   A MAGNETIZATION-TRANSFER IMAGING STUDY OF NORMAL-APPEARING WHITE-MATTER IN MULTIPLE-SCLEROSIS [J].
FILIPPI, M ;
CAMPI, A ;
DOUSSET, V ;
BARATTI, C ;
MARTINELLI, V ;
CANAL, N ;
SCOTTI, G ;
COMI, G .
NEUROLOGY, 1995, 45 (03) :478-482
[6]   Quantification of MRI lesion load in multiple sclerosis: A comparison of three computer-assisted techniques [J].
Grimaud, J ;
Lai, M ;
Thorpe, J ;
Adeleine, P ;
Wang, L ;
Barker, GJ ;
Plummer, DL ;
Tofts, PS ;
McDonald, WI ;
Miller, DH .
MAGNETIC RESONANCE IMAGING, 1996, 14 (05) :495-505
[7]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[8]  
Koopmans R A, 1993, J Neuroimaging, V3, P163
[9]   Spinal cord atrophy and disability in multiple sclerosis - A new reproducible and sensitive MRI method with potential to monitor disease progression [J].
Losseff, NA ;
Webb, SL ;
ORiordan, JI ;
Page, R ;
Wang, L ;
Barker, GJ ;
Tofts, PS ;
McDonald, WI ;
Miller, DH ;
Thompson, AJ .
BRAIN, 1996, 119 :701-708
[10]   MAGNETIC-RESONANCE-IMAGING OF RADIATION-DOSE DISTRIBUTIONS USING A POLYMER-GEL DOSIMETER [J].
MARYANSKI, MJ ;
SCHULZ, RJ ;
IBBOTT, GS ;
GATENBY, JC ;
XIE, J ;
HORTON, D ;
GORE, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (09) :1437-1455