Image processing in radiology

被引:9
作者
Dammann, F [1 ]
机构
[1] Radiol Univ Klin Tubingen, Abt Radiol Diagnost, D-72076 Tubingen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2002年 / 174卷 / 05期
关键词
computer aided radiology; computer simulation; image processing; computer assisted; artifacts; user computer interface;
D O I
10.1055/s-2002-28279
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Medical imaging processing and analysis methods have significantly improved during recent years and are now being increasingly used in clinical applications. Preprocessing algorithms are used to influence image contrast and noise. Three-dimensional visualization techniques including volume rendering and virtual endoscopy are increasingly available to evaluate sectional imaging data sets. Registration techniques have been developed to merge different examination modalities. Structures of interest can be extracted from the image data sets by various segmentation methods. Segmented structures are used for automated quantification analysis as well as for three-dimensional therapy planning, simulation and intervention guidance, including medical modelling, virtual reality environments, surgical robots and navigation systems. These newly developed methods require specialized skills for the production and postprocessing of radiological imaging data as well as new definitions of the roles of the traditional specialities. The aim of this article is to give an overview of the state-of-the-art of medical imaging processing methods, practical implications for the ragiologist's daily work and future aspects.
引用
收藏
页码:541 / 550
页数:10
相关论文
共 75 条
[1]   SEEDED REGION GROWING [J].
ADAMS, R ;
BISCHOF, L .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1994, 16 (06) :641-647
[2]  
[Anonymous], 1998, J COMPUT ASSIST TOMO
[3]  
Barker T M, 1994, Australas Radiol, V38, P106, DOI 10.1111/j.1440-1673.1994.tb00146.x
[4]   Analysis of artifacts found in endographic visualization of spiral CT scans. [J].
Bode, A ;
Dammann, F ;
Pelikan, EHW ;
Heuschmid, M ;
Schwaderer, E ;
Schaich, M ;
Claussen, CD .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (03) :245-252
[5]  
Brandt G, 2000, ORTHOPADE, V29, P645
[6]   Endoscopic sinus surgery using intraoperative computed tomography imaging for updating a three-dimensional navigation system [J].
Cartellieri, M ;
Vorbeck, F .
LARYNGOSCOPE, 2000, 110 (02) :292-296
[7]   Radiation exposure with spiral CT of the paranasal sinuses [J].
Dammann, F ;
Momino-Traserra, E ;
Remy, C ;
Pereira, PL ;
Baumann, I ;
Koitschev, A ;
Claussen, CD .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (03) :232-237
[8]   Computer-aided surgical planning for implantation of hearing aids based on CT data in a VR environments [J].
Dammann, F ;
Bode, A ;
Schwaderer, E ;
Schaich, M ;
Heuschmid, M ;
Maassen, MM .
RADIOGRAPHICS, 2001, 21 (01) :183-190
[9]   VIRTUAL-REALITY IN MEDICAL-TRAINING [J].
DUNKLEY, P .
LANCET, 1994, 343 (8907) :1218-1218
[10]  
Englmeier KH, 1997, METHOD INFORM MED, V36, P1