Simultaneous segmentation of multiple heart cavities in 3D transesophageal echocardiograms

被引:4
作者
Haak, Alexander [1 ]
Vegas-Sanchez-Ferrero, Gonzalo [2 ]
Mulder, Harriet H. [3 ]
Kirisli, Hortense A. [4 ]
Baka, Nora [4 ]
Metz, Coert [4 ]
Klein, Stefan [4 ]
Ren, Ben [5 ]
van Burken, Gerard
Pluim, Josien P. W. [3 ]
van der Steen, Antonius F. W. [1 ,6 ]
van Walsum, Theo [4 ]
Bosch, Johannes G. [1 ]
机构
[1] Erasmus MC, Rotterdam, Netherlands
[2] Univ Valladolid, Image Proc Lab, E-47002 Valladolid, Spain
[3] Ctr Med Univ Utrecht, Inst Imaging Sci, Utrecht, Netherlands
[4] Erasmus MC, Dept Med Informat & Radiol, Biomed Imaging Grp Rotterdam, Rotterdam, Netherlands
[5] Erasmus MC, Thoraxctr, Dept Cardiol, Rotterdam, Netherlands
[6] Interuniv Cardiol Inst Netherlands, Eindhoven, Netherlands
来源
2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2013年
关键词
CTA;
D O I
10.1109/ULTSYM.2013.0170
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
Three-dimensional transesophageal echocardiography (3D TEE) is an excellent modality for real-time visualization of the heart and monitoring of interventions. However, 3D TEE segmentation is still a challenging task due to the complex anatomy, the limited field of view, and typical ultrasound artifacts. To improve the usability of 3D TEE for monitoring interventions, we propose to segment all cavities within the TEE view with a multi-cavity Active Shape Model (ASM) derived from Computed Tomography Angiography (CTA) in conjunction with a tissue/blood classification based on a Gamma Mixture Model (GMM). 3D TEE image data of five patients were acquired with a Philips X7-2t matrix TEE probe. Tissue probability maps were estimated by a two class (blood/tissue) GMM. A statistical shape model containing left and right ventricle, left and right atrium and aorta (LV, LA, RV, LA, Ao) was derived from CTA scans of 151 patients by Principal Component Analysis. Models from individual cavities (ASM(part): ASM(LV) etc.) and of the whole heart (ASM(tot)) were generated. First, ASM(tot) was aligned with the 3D TEE by indicating 3 anatomical landmarks. Second, pose and shape of ASM(tot) were iteratively updated by a weighted update scheme excluding parts outside of the image sector. Third, shape and pose of each ASM(part) were initialized based on shape and pose of ASM(tot) and iteratively updated in a constrained manner to fit the tissue probability maps. All 3D TEE sets were manually outlined in multiple short and long axis views by two observers. The mean outline of both observers was compared to the ASM segmentations by calculating Dice coefficients. All patients had preoperative CTA scans which were segmented using an atlas approach. The TEE and the CTA segmentation were registered and Dice coefficients were computed. The Dice coefficients of the whole heart between the average observer and ASM segmentations were 0.91, 0.75, 0.87, 0.88, and 0.84 (interobserver variability: 0.95, 0.92, 0.92, 0.88, and 0.90) for TEE set 1 to 5 respectively. The Dice coefficient for the whole hart between CTA and TEE segmentation were 0.85, 0.80, 0.80, 0.81, and 0.71 and showed good agreement. In this work we could successfully show the accuracy and robustness of the proposed multi-cavity segmentation scheme.
引用
收藏
页码:655 / 658
页数:4
相关论文
共 11 条
[1]
LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[2]
ACTIVE SHAPE MODELS - THEIR TRAINING AND APPLICATION [J].
COOTES, TF ;
TAYLOR, CJ ;
COOPER, DH ;
GRAHAM, J .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1995, 61 (01) :38-59
[3]
MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES [J].
DICE, LR .
ECOLOGY, 1945, 26 (03) :297-302
[4]
Haak A., 2013, MIAR AE CAI IN PRESS
[5]
Evaluation of a multi-atlas based method for segmentation of cardiac CTA data: a large-scale, multicenter, and multivendor study [J].
Kirisli, H. A. ;
Schaap, M. ;
Klein, S. ;
Papadopoulou, S. L. ;
Bonardi, M. ;
Chen, C. H. ;
Weustink, A. C. ;
Mollet, N. R. ;
Vonken, E. J. ;
van der Geest, R. J. ;
van Walsum, T. ;
Niessen, W. J. .
MEDICAL PHYSICS, 2010, 37 (12) :6279-6291
[6]
elastix: A Toolbox for Intensity-Based Medical Image Registration [J].
Klein, Stefan ;
Staring, Marius ;
Murphy, Keelin ;
Viergever, Max A. ;
Pluim, Josien P. W. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) :196-205
[7]
Regression-Based Cardiac Motion Prediction From Single-Phase CTA [J].
Metz, Coert T. ;
Baka, Nora ;
Kirisli, Hortense ;
Schaap, Michiel ;
Klein, Stefan ;
Neefjes, Lisan A. ;
Mollet, Nico R. ;
Lelieveldt, Boudewijn ;
de Bruijne, Marleen ;
Niessen, Wiro J. ;
van Walsum, Theo .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (06) :1311-1325
[8]
The expectation-maximization algorithm [J].
Moon, TK .
IEEE SIGNAL PROCESSING MAGAZINE, 1996, 13 (06) :47-60
[9]
Active shape model segmentation with optimal features [J].
van Ginneken, B ;
Frangi, AF ;
Staal, JJ ;
Romeny, BMT ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) :924-933
[10]
ON THE INFLUENCE OF INTERPOLATION ON PROBABILISTIC MODELS FOR ULTRASONIC IMAGES [J].
Vegas-Sanchez-Ferrero, G. ;
Martin-Martinez, D. ;
Aja-Fernandez, S. ;
Palencia, C. .
2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, :292-295