Measurement of ejection fraction with standard thermodilution catheters

被引:6
作者
dos Santos, I
da Rocha, AF
Nascimento, FAD
Neto, JS
Valvano, JW
机构
[1] Univ Texas, Biomed Engn Program, Austin, TX 78712 USA
[2] Univ Brasilia, Dept Elect Engn, BR-70910900 Brasilia, DF, Brazil
关键词
ejection fraction; thermodilution; thermistor; digital signal processing; neural network;
D O I
10.1016/S1350-4533(02)00026-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Right ventricle ejection fraction (RVEF) is clinically used to evaluate right ventricular function. The thermodilution method can be modified to estimate the RVEF. However, this method requires a thermistor with a fast time response in order to yield correct estimates. Digital signal processing techniques that were developed in previous works, allow the use of industry-standard slow time response thermistors for the measurement EF. However, these algorithms were not automated, and the works did not present a complete evaluation of the method's performance. This article presents a modified automated version of these algorithms, and uses numerical and in vitro simulations to test their performance. In the simulations, the measured ejection fraction was compared to the true ejection fraction. RVEFs ranging from 0.20 to 0.80 were tested for heart rates ranging from 30 to 120 heart beats per min. Statistical analysis of data showed that the new method presents an improved performance. (C) 2002 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:325 / 335
页数:11
相关论文
共 14 条
[1]  
Burton AC., 1972, PHYSL BIOPHYSICS CIR, V2
[2]  
DAROCHA AF, 1998, AN 4 FOR NAC CIENC T, P207
[3]  
DAROCHA AF, 1997, THESIS U TEXAS AUSTI
[4]  
DETWEILER DK, 1976, BEST TAYLORS BASES F
[5]  
DOSSANTOS I, 2000, THESIS U BRASILIA
[6]   MEASUREMENT OF CARDIAC OUTPUT IN ANAESTHETIZED ANIMALS BY A THERMO-DILUTION METHOD [J].
FEGLER, G .
QUARTERLY JOURNAL OF EXPERIMENTAL PHYSIOLOGY AND COGNATE MEDICAL SCIENCES, 1954, 39 (03) :153-164
[7]   SEMINAR ON CLINICAL APPLICATION OF TECHNIQUES TO MEASURE BLOOD-FLOW IN MAN .2. MEASUREMENT OF BLOOD-FLOW BY THERMODILUTION [J].
GANZ, W ;
SWAN, HJC .
AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (02) :241-+
[8]  
HORI JI, 1994, IEICE T FRUND A, V5, P784
[9]  
KNOBEL E, 1997, CATETER SWAN GANZ DE
[10]   LIMITATIONS OF THERMODILUTION EJECTION FRACTION - DEGRADATION OF FREQUENCY-RESPONSE BY CATHETER MOUNTING OF FAST-RESPONSE THERMISTORS [J].
MARUSCHAK, GF ;
SCHAUBLE, JF .
CRITICAL CARE MEDICINE, 1985, 13 (08) :679-682