Blood pressure measurement in epidemiological investigations in teenagers

被引:9
作者
Coppieters, Y
Parent, F
Berghmans, L
Godin, I
Levêque, A
机构
[1] Free Univ Brussels, Sch Publ Hlth, B-1070 Brussels, Belgium
[2] Observ Sante Hainaut, Havre, Belgium
关键词
bias of measure; blood pressure; epidemiological investigation; teenagers; validation;
D O I
10.1023/A:1016250827716
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background : The use of sphygmomanometers may lead to problems in investigations on health of young people. The purpose of this paper is to present the validation of the blood pressure ( BP) collected during the survey 'Youth Heart Health' in Hainaut by using second sample of young people in Hainaut for which BP was measured by a manual taking of tension and by an electronic device. Methods: Validation was done with a control sample of 343 young with five successive BP measures: twice with the mercury sphygmomanometer and three with DXL. We compared the manual and the electronic measures in order to study the correlation between the two methods. The control sample was used in order to compare the BP measurements with the results of the survey on the health of young people in Hainaut. Results : The differences between manual systolic BP and Dinamap measures are significant (differences in averages 3.6 mmHg; d.s. 7.8; 95% CI: 2.8-4.4 mmHg; p < 0.001) and the regression coefficient is -0.015. Diastolic BP is significantly higher with the manual method than with Dinamap (differences in means: 8.2 mmHg; d.s. 7.0; 95% CI: 7.4-8.9 mmHg; p < 0.001) and the coefficient of regression is 0.096. We observe a difference in BP between the general survey and the control group (10.3 mmHg for systolic manual control and of 10.9 mmHg for systolic electronic control; 3.3 mmHg for diastolic manual control and of 11.5 mmHg for diastolic electronic control). Conclusions : The values of BP of the 'Youth Heart Health' are significantly higher. These observations indicate the difficulties in the choice of the tool for measurements of BP in epidemiological investigations in the teenagers. In order to decrease skews of observations in the measurement of BP, it is recommended to use a valid electronic instrument. Dinamap XL is an instrument of choice in such studies of young people. Environmental and organisational factors may also explain the observed difference, which means that survey's protocols should address this issue carefully.
引用
收藏
页码:901 / 906
页数:6
相关论文
共 19 条
[1]   Evaluation of the Dinamap 8100 and Omron M1 blood pressure monitors for use in children [J].
Barker, ME ;
Shiell, AW ;
Law, CM .
PAEDIATRIC AND PERINATAL EPIDEMIOLOGY, 2000, 14 (02) :179-186
[2]   Validation of automated oscillometric sphygmomanometer (HDBPM) for arterial pressure measurement during haemodialysis [J].
Cavalcanti, S ;
Marchesi, G ;
Ghidini, C .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (01) :98-101
[3]   BLOOD-PRESSURE MEASUREMENT IN CHILDHOOD EPIDEMIOLOGIC STUDIES [J].
GILLMAN, MW ;
COOK, NR .
CIRCULATION, 1995, 92 (04) :1049-1057
[4]   IDENTIFYING CHILDREN AT HIGH-RISK FOR THE DEVELOPMENT OF ESSENTIAL-HYPERTENSION [J].
GILLMAN, MW ;
COOK, NR ;
ROSNER, B ;
EVANS, DA ;
KEOUGH, ME ;
TAYLOR, JO ;
HENNEKENS, CH .
JOURNAL OF PEDIATRICS, 1993, 122 (06) :837-846
[5]  
GODIN I, 1998, TABLEAU BORD SANTE H
[6]  
Guillaume M, 1996, AM J EPIDEMIOL, V144, P867, DOI 10.1093/oxfordjournals.aje.a009021
[7]  
Mancia G, 1999, Blood Press Monit, V4, P295
[8]   Prevalence of coronary heart disease risk factors in Costa Rican adolescents [J].
Monge, R ;
Beita, O .
JOURNAL OF ADOLESCENT HEALTH, 2000, 27 (03) :210-217
[9]   Consequences of banning mercury and the cuff controversy [J].
O'Brien, E .
BLOOD PRESSURE MONITORING, 2000, 5 (01) :33-34
[10]  
O'Brien E, 1999, Blood Press Monit, V4, P53