Use of coupled open-tubular capillaries for in-line ion-exchange preconcentration of anions by capillary electrochromatography with elution by a transient isotachophoretic gradient

被引:26
作者
Hutchinson, JP
Macka, M
Avdalovic, N
Haddad, PR
机构
[1] Univ Tasmania, ACROSS, Sch Chem, Hobart, Tas 7001, Australia
[2] Dionex Chem Corp, Sunnyvale, CA 94088 USA
关键词
electrochromatography; capillary columns; isotachophoretic gradients; water analysis; environmental analysis; coupled columns; inorganic anions;
D O I
10.1016/j.chroma.2004.03.073
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Open-tubular capillaries have been joined together for use in on-column ion-exchange preconcentration of anions by capillary electrochromatography (CEC) with elution by a transient isotachophoretic gradient. This involved the coupling of a preconcentration capillary and a separation capillary using a PTFE sleeve. Such coupling allowed precise lengths of differently coated capillaries to be joined in-line to form a single multi-mode column. The different segments could be tailored to optimize a separation by either altering the length of each segment to precisely manipulate the amount of stationary phase present or by changing the internal diameter of each segment to alter the phase ratio in the chromatographic column without affecting the path length for UV detection. In this work, a segmented in-line capillary was used in conjunction with a fluoride-octanesulfonate discontinuous electrolyte system to increase the number of anions that could be preconcentrated and separated. Quaternary ammonium functionalised latex particles were used for creating the preconcentration segment and the separation segment was coated with poly(diallyldimethylammonium chloride). This allowed the detection of trace anions in drinking water and in situ sampling of river water for the analysis of trace inorganic anions. The repeatability of producing the quaternary ammonium functionalized latex-coated segments was assessed and the effect of segmentation on peak efficiency was investigated. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 48 条
[1]   On-line ion-exchange preconcentration in a flow injection system coupled to capillary electrophoresis for the direct determination of UV absorbing anions [J].
Arce, L ;
Kuban, P ;
Ríos, A ;
Valcárcel, M ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) :39-44
[2]   Flow injection-capillary electrophoresis coupling to automate on-line sample treatment for the determination of inorganic ions in waters [J].
Arce, L ;
Ríos, A ;
Valcárcel, M .
JOURNAL OF CHROMATOGRAPHY A, 1997, 791 (1-2) :279-287
[3]   NEW APPROACH TO THE ANALYSIS OF LOW-LEVELS OF ANIONS IN WATER [J].
BONDOUX, G ;
JANDIK, P ;
JONES, WR .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :79-88
[4]   Open-tubular ion-exchange capillary electrochromatography of inorganic anions [J].
Breadmore, MC ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYST, 2000, 125 (07) :1235-1241
[5]   On-column ion-exchange preconcentration of inorganic anions in open tubular capillary electrochromatography with elution using transient-isotachophoretic gradients. 3. Implementation and method development [J].
Breadmore, MC ;
Palmer, AS ;
Curran, M ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2002, 74 (09) :2112-2118
[6]   On capillary ion-exchange preconcentration of inorganic anions in open-tubular capillary electrochromatography with elution using transient-isotachophoretic gradients. 2. Characterization of the isotachophoretic gradient [J].
Breadmore, MC ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :820-828
[7]   On-capillary ion-exchange preconcentration of inorganic anions using open-tubular capillaries followed by elution with a transient isotachophoretic gradient [J].
Breadmore, MC ;
Boyce, MC ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYST, 2000, 125 (05) :799-802
[8]   Velocity-difference induced focusing of nucleotides in capillary electrophoresis with a dynamic pH junction [J].
Britz-McKibbin, P ;
Bebault, GM ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1729-1735
[9]   LARGE-VOLUME STACKING OF ANIONS IN CAPILLARY ELECTROPHORESIS USING AN ELECTROOSMOTIC FLOW MODIFIER AS A PUMP [J].
BURGI, DS .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3726-3729
[10]   ONLINE PRECONCENTRATION OF TRIAZINE HERBICIDES WITH TANDEM OCTADECYL CAPILLARIES-CAPILLARY ZONE ELECTROPHORESIS [J].
CAI, J ;
ELRASSI, Z .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (6-7) :1179-1192