Damage identification based on response-only measurements using cepstrum analysis and artificial neural networks

被引:61
作者
Dackermann, Ulrike [1 ]
Smith, Wade A. [2 ]
Randall, Robert B. [2 ]
机构
[1] Univ Technol Sydney, Sch Civil & Environm Engn, Fac Engn & Informat Technol, Sydney, NSW 2007, Australia
[2] Univ New S Wales, Sch Mech & Mfg Engn, Fac Engn, Sydney, NSW, Australia
来源
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL | 2014年 / 13卷 / 04期
基金
澳大利亚研究理事会;
关键词
Structural health monitoring; frequency response function; cepstrum analysis; artificial neural networks; damage identification; principal component analysis; multiple-storey framed structure; operational modal analysis; civil engineering structure; OPERATIONAL MODAL-ANALYSIS; FREQUENCY; EXTRACTION; LOCATION; POLES;
D O I
10.1177/1475921714542890
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This article presents a response-only structural health monitoring technique that utilises cepstrum analysis and artificial neural networks for the identification of damage in civil engineering structures. The method begins by applying cepstrum-based operational modal analysis, which separates source and transmission path effects to determine the structure's frequency response functions from response measurements only. Principal component analysis is applied to the obtained frequency response functions to reduce the data size, and structural damage is then detected using a two-stage ensemble of artificial neural networks. The proposed method is verified both experimentally and numerically using a laboratory two-storey framed structure and a finite element representation, both subjected to a single excitation. The laboratory structure is tested on a large-scale shake table generating ambient loading of Gaussian distribution. In the numerical investigation, the same input is applied to the finite model, but the obtained responses are polluted with different levels of white Gaussian noise to better replicate real-life conditions. The damage is simulated in the experimental and numerical investigations by changing the condition of individual joint elements from fixed to pinned. In total, four single joint changes are investigated. The results of the investigation show that the proposed method is effective in identifying joint damage in a multi-storey structure based on response-only measurements in the presence of a single input. Because the technique does not require a precise knowledge of the excitation, it has the potential for use in online structural health monitoring. Recommendations are given as to how the method could be applied to the more general multiple-input case.
引用
收藏
页码:430 / 444
页数:15
相关论文
共 31 条
[1]  
Alyuda Research Inc, 2006, AL NEUROINTELLIGENCE
[2]  
[Anonymous], 1963, PROC S TIME SER ANAL
[3]  
[Anonymous], 2010, DISCRETE TIME SIGNAL
[4]  
[Anonymous], 2011, IND AEROSPACE AUTOMO
[5]  
Chang PC., 2003, STRUCT HLTH MONIT, V2, P257, DOI [DOI 10.1177/1475921703036169, 10.1177/1475921703036169]
[6]   CEPSTRUM - GUIDE TO PROCESSING [J].
CHILDERS, DG ;
SKINNER, DP ;
KEMERAIT, RC .
PROCEEDINGS OF THE IEEE, 1977, 65 (10) :1428-1443
[7]  
Choudhury AR, 1996, P SOC PHOTO-OPT INS, V2768, P934
[8]  
Dackermann U, 2013, P 6 INT C STRUCT HLT
[9]   Identification of member connectivity and mass changes on a two-storey framed structure using frequency response functions and artificial neural networks [J].
Dackermann, Ulrike ;
Li, Jianchun ;
Samali, Bijan .
JOURNAL OF SOUND AND VIBRATION, 2013, 332 (16) :3636-3653
[10]   Operational modal analysis in the presence of harmonic excitations by the use of transmissibility measurements [J].
Devriendt, Christof ;
De Sitter, Gert ;
Vanlanduit, Steve ;
Guillaume, Patrick .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2009, 23 (03) :621-635