摘要
The use of diamond detectors in radiotherapy and their potential advantage over silicon diodes and ionisation chambers is reviewed. Preliminary results on the performance of CVD diamond detectors in an X-ray beam are presented. While the devices are sufficiently sensitive, applications as dosimeters are at present limited by time dependent effects. Prospects for further work are described.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 6 条
[1]   Recent results from diamond microstrip detectors - Diamond detectors collaboration (RD42) [J].
Bauer, C ;
Baumann, I ;
Colledani, C ;
Conway, J ;
Delpierre, P ;
Djama, F ;
Dulinski, W ;
Fallou, A ;
Gan, KK ;
Gilmore, RS ;
Grigoriev, E ;
Hallewell, G ;
Han, S ;
Hessing, T ;
Hrubec, J ;
Husson, D ;
Kagan, H ;
Kania, D ;
Kass, R ;
Kinnison, W ;
Knopfle, KT ;
Krammer, M ;
Llewellyn, TJ ;
Manfredi, PF ;
Pan, LS ;
Pernegger, H ;
Pernicka, M ;
Re, V ;
Roe, S ;
Rudge, A ;
Schaeffer, M ;
Schnetzer, S ;
Somalwar, S ;
Speziali, V ;
Stone, R ;
Tapper, RJ ;
Tesarek, R ;
Trischuk, W ;
Turchetta, R ;
Thomson, GB ;
Wagner, R ;
Weilhammer, P ;
White, C ;
Zoeller, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3) :202-206
[2]   Radiation hardness studies of CVD diamond detectors [J].
Bauer, C ;
Baumann, I ;
Colledani, C ;
Conway, J ;
Delpierre, P ;
Djama, F ;
Dulinski, W ;
Fallou, A ;
Gan, KK ;
Gilmore, RS ;
Grigoriev, E ;
Hallewell, G ;
Han, S ;
Hessing, T ;
Honschied, K ;
Hrubec, J ;
Husson, D ;
Kagan, H ;
Kania, D ;
Kass, R ;
Kinnison, W ;
Knopfle, KT ;
Krammer, M ;
Llewellyn, TJ ;
Manfredi, PF ;
Pan, LS ;
Pernegger, H ;
Pernicka, M ;
Plano, R ;
Re, V ;
Roe, S ;
Rudge, A ;
Schaeffer, M ;
Schnetzer, S ;
Somalwar, S ;
Speziali, V ;
Stone, R ;
Tapper, RJ ;
Tesarek, R ;
Trischuk, W ;
Turchetta, R ;
Thomson, GB ;
Wagner, R ;
Weilhammer, P ;
White, C ;
Ziock, H ;
Zoeller, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3) :207-211
[3]   EVALUATION OF A PTW DIAMOND DETECTOR FOR ELECTRON-BEAM MEASUREMENTS [J].
HEYDARIAN, M ;
HOBAN, PW ;
BECKHAM, WA ;
BORCHARDT, IM ;
BEDDOE, AH .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (08) :1035-1042
[4]   DIAMOND RADIATION DETECTORS [J].
KEDDY, RJ ;
NAM, TL .
RADIATION PHYSICS AND CHEMISTRY, 1993, 41 (4-5) :767-773
[5]   EVALUATION OF THE DOSIMETRIC CHARACTERISTICS OF A DIAMOND DETECTOR FOR PHOTON-BEAM MEASUREMENTS [J].
RUSTGI, SN .
MEDICAL PHYSICS, 1995, 22 (05) :567-570
[6]   APPLICATION OF A NATURAL DIAMOND DETECTOR FOR THE MEASUREMENT OF RELATIVE DOSE DISTRIBUTIONS IN RADIOTHERAPY [J].
VATNITSKY, S ;
JARVINEN, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (01) :173-184