Pharmacokinetics of three gadolinium chelates with different molecular sizes shortly after intravenous injection in rabbits - Relevance to MR angiography

被引:38
作者
Corot, C [1 ]
Violas, X [1 ]
Robert, P [1 ]
Port, M [1 ]
机构
[1] Guerbert, Biol Res, F-95943 Roissy, France
关键词
blood pool agents; MR angiography; blood gadolinium concentration;
D O I
10.1097/00004424-200004000-00001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO mimic an MR angiographic protocol, an experimental model was developed in rabbits to determine gadolinium concentrations in blood early after injection. Contrast agents with different molecular sizes were compared. METHODS. The influence of injection parameters (injection rate, duration of injection, volume of injection, dose) was assessed, and two blood pool agents (P760, P717) were compared with the low-molecular-weight Gd-DOTA under similar conditions. RESULTS. Two main phases were identified: bolus and postbolus, Injection parameters strongly influenced the pattern of the bolus phase, but the postbolus phase was sensitive only to the injected dose. The blood pool agents presented a bolus phase profile similar to that of Gd-DOTA, but 45 seconds after injection, 84% of P717 molecules were still present in the blood compartment, compared with 65% of P760 molecules and only 51% of Gd-DOTA molecules. CONCLUSIONS. Blood pool agents are useful for MR angiographic protocols involving the postbolus phase. In protocols in which only the bolus phase is imaged, blood pool agents provide similar data to Gd-DOTA, provided that the injection rate, iso-T1 efficiency dose, and volume are similar.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 19 条
[1]  
BOOS M, 1999, P INT SOC MAGN RES M, P1175
[2]   RATIONALE AND APPLICATIONS FOR MACROMOLECULAR GD-BASED CONTRAST AGENTS [J].
BRASCH, RC .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) :282-287
[3]  
COROT C, IN PRESS J MAGN RESO
[4]   Steady-state and dynamic MR angiography with MS-325: Initial experience in humans [J].
Grist, TM ;
Korosec, FR ;
Peters, DC ;
Witte, S ;
Walovitch, RC ;
Dolan, RP ;
Bridson, WE ;
Yucel, EK ;
Mistretta, CA .
RADIOLOGY, 1998, 207 (02) :539-544
[5]  
GROSS DR, 1994, ANIMAL MODELS CARDIO, V153, P373
[6]  
Kouwenhoven M, 1997, ACTA RADIOL, V38, P57
[7]  
Kroft LJM, 1999, JMRI-J MAGN RESON IM, V9, P777, DOI 10.1002/(SICI)1522-2586(199906)9:6<777::AID-JMRI4>3.0.CO
[8]  
2-Y
[9]   Infarcted myocardium in pigs: MR imaging enhanced with slow-interstitial-diffusion gadolinium compound P760 [J].
Kroft, LJM ;
Doornbos, J ;
van der Geest, RJ ;
Benderbous, S ;
de Roos, A .
RADIOLOGY, 1999, 212 (02) :467-473
[10]   Optimizing three-dimensional gadolinium-enhanced magnetic resonance angiography - Original investigation [J].
Maki, JH ;
Prince, MR ;
Chenevert, TC .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :528-537