Contact mechanics of the medial tibial plateau after implantation of a medial meniscal allograft - A human cadaveric study

被引:82
作者
Alhalki, MM
Hull, ML
Howell, SM
机构
[1] Univ Calif Davis, Dept Mech Engn, Biomed Engn Grad Grp, Davis, CA 95616 USA
[2] David Grant Med Ctr, Clin Invest Facil, Travis AFB, CA USA
关键词
D O I
10.1177/03635465000280031501
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The goal of this study was to determine how well a medial meniscal allograft restores the normal contact mechanics of the medial tibial plateau at the time of implantation. We measured maximum pressure, mean pressure, and contact area of the intact human cadaveric knee, the knee after meniscectomy, the knee with the original meniscus removed and reimplanted as an autograft, and the knee with an allograft, Measurements were made using pressure-sensitive film in 10 specimens loaded in compression to 1000 N at 0 degrees, 15 degrees, 30 degrees, and 45 degrees of flexion, The autograft and the allograft were identically implanted by cementing bone plugs attached to the meniscal horns in anatomic transtibial tunnels and suturing the outer edge of the meniscus to the remnant of the original meniscus, A medial meniscal allograft did not consistently restore normal contact mechanics because the process of implantation and the degree of match between the original and allograft meniscus affected the immediate load-bearing performance of the transplant. However, the allograft did significantly reduce the contact pressure compared with the knee after meniscectomy. If the results from this study can be extrapolated to patients, then using an allograft to restore contact mechanics to normal may require improvements in surgical technique and graft selection.
引用
收藏
页码:370 / 376
页数:7
相关论文
共 20 条
[1]   How three methods for fixing a medial meniscal autograft affect tibial contact mechanics [J].
Alhalki, MM ;
Howell, SM ;
Hull, ML .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (03) :320-328
[2]   Is it important to secure the hems during lateral meniscal transplantation? A cadaveric study [J].
Chen, MI ;
Branch, TP ;
Hutton, WC .
ARTHROSCOPY, 1996, 12 (02) :174-181
[3]  
FITHIAN DC, 1990, CLIN ORTHOP RELAT R, P19
[4]  
Garrett J C, 1996, Am J Knee Surg, V9, P32
[5]   A high-accuracy three-dimensional coordinate digitizing system for reconstructing the geometry of diarthrodial joints [J].
Haut, TL ;
Hull, ML ;
Howell, SM .
JOURNAL OF BIOMECHANICS, 1998, 31 (06) :571-577
[6]  
HAUT TL, 2000, IN PRESS J ORTHOP RE
[7]   PARTIAL VERSUS TOTAL MENISCECTOMY - A PROSPECTIVE, RANDOMIZED STUDY WITH LONG-TERM FOLLOW-UP [J].
HEDE, A ;
LARSEN, E ;
SANDBERG, H .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :118-121
[8]  
Kuhn JE, 1996, CLIN SPORT MED, V15, P537
[9]   An in vitro osteotomy method to expose the medial compartment of the human knee [J].
Martens, TA ;
Hull, ML ;
Howell, SM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (04) :379-385
[10]   Transplantation of fresh-frozen menisci: An experimental study in dogs [J].
Mikic, ZD ;
Brankov, MZ ;
Tubic, MV ;
Lazetic, AB .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1997, 13 (05) :579-583