Separation-free electrochemical immunosensor strategies

被引:14
作者
Killard, AJ [1 ]
Smyth, MR [1 ]
机构
[1] Natl Ctr Sensor Res, Sch Chem Sci, Dublin 9, Ireland
关键词
immunosensor; separation-free; electrochemical; membrane-based; enzyme-channelling; bulk solution scavenging; hetero-bifunctional shuttles; electrically-wired;
D O I
10.1080/00032710008543135
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The simplification of the assay strategy is an essential development for the commercial success of immunosensors. The problems associated with assay simplification stem from the fact that immune recognition is not accompanied by an easily detectable event. Direct methods such as those based on optical systems have circumvented such problems by measuring mass changes. However, such devices are not so amenable to instrumental simplification. Electrochemical methods have so far offered the best prospects for commercial biosensors. Success has only occurred with enzyme-based biosensors measuring simple biochemical molecules such as glucose, lactate and creatinine. The use of antibody-based assay strategies requires the introduction of electrochemical labels. Introduction of such species results in greater complexity, accompanied by a series of assay steps. This extension in assay complexity is in direct opposition to the concept of the biosensor: simplicity. Several strategies have been taken to remove these assay steps and reduce the complexity of the immunoassay. Such strategies may contribute to the application of Immunosensors as a serious commercial proposition.
引用
收藏
页码:1451 / 1465
页数:15
相关论文
共 26 条
[1]  
DIAMIND D, 1998, PRINCIPLES CHEM BIOL
[2]   SEPARATION-FREE SANDWICH ENZYME IMMUNOASSAYS USING MICROPOROUS GOLD ELECTRODES AND SELF-ASSEMBLED MONOLAYER IMMOBILIZED CAPTURE ANTIBODIES [J].
DUAN, CM ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1369-1377
[3]   Second-order kinetic analysis of IAsys biosensor data: Its use and applicability [J].
Edwards, PR ;
Maule, CH ;
Leatherbarrow, RJ ;
Winzor, DJ .
ANALYTICAL BIOCHEMISTRY, 1998, 263 (01) :1-12
[4]   Enzyme-immunoassays for polychlorinated biphenyls: structural aspects of hapten-antibody binding [J].
Franek, M ;
Pouzar, V ;
Kolar, V .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :163-176
[5]  
Hansen EH, 1996, J MOL RECOGNIT, V9, P316, DOI 10.1002/(SICI)1099-1352(199634/12)9:5/6<316::AID-JMR276>3.0.CO
[6]  
2-4
[7]   Evaluation of culture enrichment procedures for use with Salmonella detection immunoassay [J].
Huang, HS ;
Garcia, MM ;
Brooks, BW ;
Nielsen, K ;
Ng, SP .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1999, 51 (2-3) :85-94
[8]   A one-step, separation-free amperometric enzyme immunosensor [J].
Ivnitski, D ;
Rishpon, J .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (04) :409-417
[9]   An amperometric biosensor for real-time analysis of molecular recognition [J].
Ivnitski, D ;
Wolf, T ;
Solomon, B ;
Fleminger, G ;
Rishpon, J .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 45 (01) :27-32
[10]   Separation-free electrochemical immunosensor for rapid determination of atrazine [J].
Keay, RW ;
McNeil, CJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (09) :963-970