摘要
Here we describe for the first time a cell-based scintillation proximity assay using membrane soluble scintillants (MSS). MSS have a scintillant 'head' group (2,5-diphenyloxazole) attached to a lipophilic 'tail.' MSS do not scintillate in an aqueous environment in the presence of a radioactive source: however, in a non-aqueous environment, such as a lipid bilayer (e.g., liposome or cell membrane), scintillation does occur. MSS can be incorporated into liposomes. When these MSS-containing liposomes are fused with the plasma membranes of cells in culture the MSS are incorporated into the cell membrane. Radiolabelled molecules in close proximity to the cell membrane will then elicit a scintillation signal. This system has been used to successfully monitor [C-14] methionine uptake in HeLa cells and may be used in radiochemical and radioligand binding assays either in vivo or on microsomal preparations obtained from tissues. This new scintillation proximity technology could be readily adapted for high-throughput screening. (C) 2002 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:857 / 863
页数:7
相关论文
共 8 条
[1]
Cytostar-T scintillating microplate assay for measurement of sodium-dependent bile acid uptake in transfected HEK-293 cells [J].
Bonge, H ;
Hallén, S ;
Fryklund, J ;
Sjöström, JE .
ANALYTICAL BIOCHEMISTRY, 2000, 282 (01) :94-101
[2]
Synthesis and scintillating efficiencies of 4-functionalised-2,5-diphenyloxazoles [J].
Clapham, B ;
Richards, AJ ;
Wood, ML ;
Sutherland, AJ .
TETRAHEDRON LETTERS, 1997, 38 (52) :9061-9064
[3]
Measurement of calcium flux through ionotropic glutamate receptors using Cytostar-T scintillating microplates [J].
Cushing, A ;
Price-Jones, MJ ;
Graves, R ;
Harris, AJ ;
Hughes, KT ;
Bleakman, D ;
Lodge, D .
JOURNAL OF NEUROSCIENCE METHODS, 1999, 90 (01) :33-36
[4]
Noninvasive, real-time method for the examination of thymidine uptake events - Application of the method to V-79 cell synchrony studies [J].
Graves, R ;
Davies, R ;
Brophy, G ;
OBeirne, G ;
Cook, N .
ANALYTICAL BIOCHEMISTRY, 1997, 248 (02) :251-257
[5]
SCINTILLATION PROXIMITY ASSAY (SPA) - NEW METHOD OF IMMUNOASSAY - DIRECT AND INHIBITION MODE DETECTION WITH HUMAN-ALBUMIN AND RABBIT ANTIHUMAN ALBUMIN [J].
HART, HE ;
GREENWALD, EB .
MOLECULAR IMMUNOLOGY, 1979, 16 (04) :265-267
[6]
Determination of the depth of BODIPY probes in model membranes by parallax analysis of fluorescence quenching [J].
Kaiser, RD ;
London, E .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1998, 1375 (1-2) :13-22
[7]
SCINTILLATION PROXIMITY ASSAY - A SENSITIVE AND CONTINUOUS ISOTOPIC METHOD FOR MONITORING LIGAND RECEPTOR AND ANTIGEN-ANTIBODY INTERACTIONS [J].
UDENFRIEND, S ;
GERBER, L ;
NELSON, N .
ANALYTICAL BIOCHEMISTRY, 1987, 161 (02) :494-500
[8]
SCINTILLATION PROXIMITY RADIOIMMUNOASSAY UTILIZING I-125 LABELED LIGANDS [J].
UDENFRIEND, S ;
GERBER, LD ;
BRINK, L ;
SPECTOR, S .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1985, 82 (24) :8672-8676