Simple method for colorimetric spot-test quantitative analysis of Fe(III) using a computer controlled hand-scanner

被引:80
作者
Kompany-Zareh, M [1 ]
Mansourian, M
Ravaee, F
机构
[1] Inst Adv Studies Basic Sci, Dept Chem, Gava Zang 45195, Zanjan, Iran
[2] Yasuj Univ, Dept Chem, Yasuj 75914353, Iran
关键词
hand-scanner; spot-test; artificial neural networks; orthogonal design; Fe;
D O I
10.1016/S0003-2670(02)00871-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a very simple and rapid method for colorimetric spot-test determination of Fe(III) utilizing a hand-scanner. Artificial neural networks with back propagation algorithm coupled with an orthogonal array design were applied to the modeling and optimization of scanner parameters. Orthogonal design was utilized to design the experimental protocol, in which scanner parameters including dot per inch (dpi), brightness (btn), contrast (ent), and mixed gamma (mgm) were varied simultaneously. Then, using ANNs, optimum experimental conditions in terms of sensitivity were generated. Calibration curves were obtained by plotting first principal component obtained from color intensities (red, green, and blue) against the concentration of Fe(III) from 6 to 45 mmol l(-1) Fe(III). Error less than 4% was obtained for all of the experiments. The method was successfully applied for analysis of Fe(III) in a synthetic iron steel. Totally, the obtained results showed that the method is applicable for accurate, precise, rapid, and low cost colorimetric analysis including spot-test procedures. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 13 条
[1]   MULTIDIMENSIONAL DETECTION AND ANALYSIS IN THIN-LAYER CHROMATOGRAPHY [J].
BURNS, DH ;
CALLIS, JB ;
CHRISTIAN, GD .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1986, 5 (02) :50-52
[2]  
DEMUTH H, 1994, NEURAL NETWORK TOOLB, pCH13
[3]   Stability indicating spectrodensitometric determination of ranitidine hydrochloride using linear and non-linear regression [J].
El-Bayoumi, AEA ;
El-Shanawany, A ;
El-Sadek, ME ;
El-Sattar, AA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (04) :867-873
[4]  
Feigl F, 1972, SPOT TEST INORGANIC
[5]   Quantitative measurements of ammonium, hydrogenophosphate and Cu(II) by diffuse reflectance spectrometry [J].
Ghauch, A ;
Rima, J ;
Charef, A ;
Suptil, J ;
Fachinger, C ;
Martin-Bouyer, M .
TALANTA, 1999, 48 (02) :385-392
[6]   NEURAL NETWORKS IN ANALYTICAL-CHEMISTRY [J].
KATEMAN, G .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1993, 19 (02) :135-142
[7]   ORTHOGONAL ARRAY DESIGN AS A CHEMOMETRIC METHOD FOR THE OPTIMIZATION OF ANALYTICAL PROCEDURES .5. 3-LEVEL DESIGN AND ITS APPLICATION IN MICROWAVE DISSOLUTION OF BIOLOGICAL SAMPLES [J].
LAN, WG ;
WONG, MK ;
CHEN, N ;
SIN, YM .
ANALYST, 1995, 120 (04) :1115-1124
[8]  
LIANG Y, 1996, RECENT DEV SCI OPTIC, P161
[9]  
SANCHEZ FG, 1993, J CHROMATOGR A, V655, P31
[10]  
TOCHSTONE JC, 1983, PRACTICE THIN LAYER, P250