BioMatrix® Biolimus A9®-eluting coronary stent:: a next-generation drug-eluting stent for coronary artery disease

被引:82
作者
Grube, Eberhard [1 ]
Buellesfeld, Lutz [1 ]
机构
[1] HELIOS Heart Ctr Siegburg, Dept Cardiol Angiol, D-53721 Siegburg, Germany
关键词
Biolimus A9 (R); drug-eluting coronary stents; restenosis;
D O I
10.1586/17434440.3.6.731
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Drug-eluting stent technology consisting of a bare metal stent, carrier coating, bioactive drug and delivery system, offers an almost infinite range of possible device configurations. A growing understanding of the mechanisms of restenosis allows for the design of synergistic functions within these components, thus providing a basis for new and improved products. The BioMatrix stent (Biosensors Interventional Technologies Pte Ltd., Singapore) elutes the new sirolimus derivative Biolimus A9(R) from a biodegradable polylactic acid polymer. Biolimus A9 possesses enhanced anti-inflammatory and antiproliferative activity with an improved pharmacokinetic profile. Permanent polymer-carrier-based platforms may be associated with inflammation, late thrombosis and restenosis. The BioMatrix, with its asymmetric and abluminal coating, releases Biolimus A9 into the vessel wall while the polylactic acid polymer is resorbed by surrounding tissues. Clinical studies have demonstrated the BioMatrix to be well tolerated and effective, and it has now become the subject of an aggressive clinical program.
引用
收藏
页码:731 / 741
页数:11
相关论文
共 37 条
[1]   In-stent stenosis: pathology and implications for the development of drug eluting stents [J].
Bennett, MR .
HEART, 2003, 89 (02) :218-224
[2]  
Biondi-Zoccai Giuseppe G L, 2003, Ital Heart J, V4, P271
[3]   The in vivo effect of rapamycin derivative SDZ RAD on lymphocyte proliferation [J].
Böhler, T ;
Waiser, J ;
Budde, K ;
Lichter, S ;
Jauho, A ;
Fritsche, L ;
Korn, A ;
Neumayer, HH .
TRANSPLANTATION PROCEEDINGS, 1998, 30 (05) :2195-2197
[4]   Drug-eluting stents: A mechanical and pharmacologic approach to coronary artery disease [J].
Dobesh, PP ;
Stacy, ZA ;
Ansara, AJ ;
Enders, JM .
PHARMACOTHERAPY, 2004, 24 (11) :1554-1577
[5]   Extracellular matrix changes in stented human coronary arteries [J].
Farb, A ;
Kolodgie, FD ;
Hwang, JY ;
Burke, AP ;
Tefera, K ;
Weber, DK ;
Wight, TN ;
Virmani, R .
CIRCULATION, 2004, 110 (08) :940-947
[6]   Determination of residual stresses in a boron fibre/aluminium matrix composite [J].
Gasparyan, SH ;
Andrianopoulos, NP .
APPLIED COMPOSITE MATERIALS, 2005, 12 (02) :65-72
[7]  
GRUBE E, 2005, EUR PAR COURS REV PA
[8]  
GRUBE E, 2005, TRANSCATHETER CARDIO
[9]   TRANS-LUMINAL DILATATION OF CORONARY-ARTERY STENOSIS [J].
GRUNTZIG, A .
LANCET, 1978, 1 (8058) :263-263
[10]  
GUANGLIUMI G, 2003, ITAL HEART J, V4, P236