Flow injection on-line sorption separation and preconcentration with a knotted reactor for electrothermal atomic absorption spectrometric determination of lead in biological and environmental samples

被引:75
作者
Yan, XP [1 ]
Adams, F [1 ]
机构
[1] UNIV ANTWERP,DEPT CHEM,B-2610 ANTWERP,BELGIUM
关键词
flow injection; on-line separation and preconcentration; electrothermal atomic absorption spectrometry; knotted reactor; lead; biological and environmental samples;
D O I
10.1039/a607430h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective and robust Bow injection on-line sorption separation and preconcentration procedure was developed for the ETAAS determination of (ultra)trace amounts of lead in biological and environmental samples. With the use of diethyldithiophosphate as complexing agent and citric acid as masking agent, the analyte complex was selectively formed and adsorbed onto the inner, walls of a PTFE knotted reactor at pH 0.5-3.5 with removal of the high-content salts in saline water and most of the other metals in digested biological and environmental samples. The collected analyte complex was eluted quantitatively with 35 mu l of ethanol and all the eluate was directly introduced into the graphite tube without a L'vov platform by an air Bow. Neither a pre-heating step nor precise timing was needed during elution and eluate introduction. ETAAS determination of the concentrated analyte was carried out in parallel with the next preconcentration cycle, An enhancement factor of 125 and a detection limit (3s) of 4.8 ng l(-1) Pb, along with a sampling frequency of 31 h(-1), were achieved with a 60 s loading time at a sample Bow rate of 5.4 mi min(-1). The precision for 11 replicate determinations at the 0.5 mu g l(-1) Pb level was 2.1% (RSD), The analytical results for a number of biological and environmental certified reference materials were in good agreement with the certified values.
引用
收藏
页码:459 / 464
页数:6
相关论文
共 17 条
[1]   DETERMINATION OF TRACE-METALS IN SEAWATER BY GRAPHITE-FURNACE ATOMIC-ABSORPTION FOLLOWING ONLINE SEPARATION AND PRECONCENTRATION [J].
AZEREDO, LC ;
STURGEON, RE ;
CURTIUS, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (01) :91-98
[2]   DESIGN OF A CONTINUOUS-FLOW 2-STEP EXTRACTION SAMPLE WORK-UP SYSTEM FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BACKSTROM, K ;
DANIELSSON, LG .
ANALYTICA CHIMICA ACTA, 1990, 232 (02) :301-315
[3]   DESIGN AND EVALUATION OF AN ONLINE MICROCOLUMN PRE-CONCENTRATION TECHNIQUE FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BEINROHR, E ;
CAKRT, M ;
RAPTA, M ;
TARAPCI, P .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :1005-1007
[4]   DETERMINATION OF COPPER IN WATER AND RICE SAMPLES BY FLAME ATOMIC-ABSORPTION SPECTROMETRY WITH FLOW-INJECTION ONLINE ADSORPTION PRECONCENTRATION USING A KNOTTED REACTOR [J].
CHEN, HW ;
XU, SK ;
FANG, ZL .
ANALYTICA CHIMICA ACTA, 1994, 298 (02) :167-173
[5]   ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF MOLYBDENUM IN WATER, HUMAN HAIR AND HIGH-PURITY REAGENTS WITH FLOW-INJECTION ONLINE COPRECIPITATION PRECONCENTRATION [J].
CHEN, HW ;
XU, SK ;
FANG, ZL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (08) :533-537
[6]  
Fang Z., 1995, FLOW INJECTION ATOMI
[7]  
Fang Z., 1993, FLOW INJECTION SEPAR
[8]   DETERMINATION OF CADMIUM IN BIOLOGICAL-MATERIALS BY FLAME ATOMIC-ABSORPTION SPECTROMETRY WITH FLOW-INJECTION ONLINE SORPTION PRECONCENTRATION [J].
FANG, ZL ;
XU, SK ;
DONG, LP ;
LI, WQ .
TALANTA, 1994, 41 (12) :2165-2172
[9]   FLOW-INJECTION ONLINE COPRECIPITATION PRECONCENTRATION FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
DONG, LP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :439-445
[10]   SELECTIVE FLOW-INJECTION SORBENT EXTRACTION FOR DETERMINATION OF CADMIUM, COPPER AND LEAD IN BIOLOGICAL AND ENVIRONMENTAL-SAMPLES BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
MA, RL ;
VANMOL, W ;
ADAMS, F .
ANALYTICA CHIMICA ACTA, 1994, 293 (03) :251-260