Image Artifacts in Concurrent Transcranial Magnetic Stimulation (TMS) and fMRI Caused by Leakage Currents: Modeling and Compensation

被引:35
作者
Weiskopf, Nikolaus [1 ]
Josephs, Oliver [1 ]
Ruff, Christian C. [1 ,6 ]
Blankenburg, Felix [1 ,4 ,5 ,6 ]
Featherstone, Eric [1 ]
Thomas, Anthony [7 ]
Bestmann, Sven [1 ,3 ]
Driver, Jon [1 ,6 ]
Deichmann, Ralf [1 ,2 ]
机构
[1] UCL, UCL Inst Neurol, Wellcome Trust Ctr Neuroimaging, London WC1N 3BG, England
[2] Univ Hosp, Brain Imaging Ctr, Frankfurt, Germany
[3] UCL, UCL Inst Neurol, Sobell Dept Motor Neurosci & Movement Disorders, London WC1N 3BG, England
[4] Charite Univ Med Berlin, Dept Neurol, Berlin, Germany
[5] Charite Univ Med Berlin, Bernstein Ctr Computat Neurosci, Berlin, Germany
[6] UCL, UCL Inst Cognit Neurosci, London WC1N 3BG, England
[7] Magstim Co Ltd, Whitland, Wales
基金
英国惠康基金; 英国医学研究理事会; 英国生物技术与生命科学研究理事会;
关键词
transcranial magnetic stimulation; TMS; functional magnetic resonance imaging; fMRI; MR artifacts; leakage current; DISTORTION; CORTEX;
D O I
10.1002/jmri.21749
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To characterize and eliminate a new type of image artifact in concurrent transcranial magnetic stimulation and functional MRI (TMS-fMRI) caused by small leakage currents originating from the high-voltage capacitors in the TMS stimulator system. Materials and Methods: The artifacts in echo-planar images (EPI) caused by leakage currents were characterized and quantified in numerical simulations and phantom studies with different phantom-coil geometries. A relay-diode combination was devised and inserted in the TMS circuit that shorts the leakage current. Its effectiveness for artifact reduction was assessed in a phantom scan resembling a realistic TMS-fMRI experiment. Results: The leakage-current-induced signal changes exhibited a multipolar spatial pattern and the maxima exceeded 1% at realistic coil-cortex distances. The relay-diode combination effectively reduced the artifact to a negligible level. Conclusion: The leakage-current artifacts potentially obscure effects of interest or lead to false-positives. Since the artifact depends on the experimental setup and design (eg. amplitude of the leakage current, coil orientation, paradigm. EPI parameters), we recommend its assessment for each experiment. The relay-diode combination can eliminate the artifacts if necessary.
引用
收藏
页码:1211 / 1217
页数:7
相关论文
共 21 条
[1]   Artifacts caused by transcranial magnetic stimulation coils and EEG electrodes in T2*-weighted echo-planar imaging [J].
Baudewig, J ;
Paulus, W ;
Frahm, J .
MAGNETIC RESONANCE IMAGING, 2000, 18 (04) :479-484
[2]   On the synchronization of transcranial magnetic stimulation and functional echo-planar imaging [J].
Bestmann, S ;
Baudewig, J ;
Frahm, J .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :309-316
[3]   Mapping causal interregional influences with concurrent TMS-fMRI [J].
Bestmann, Sven ;
Ruff, Christian C. ;
Blankenburg, Felix ;
Weiskopf, Nikolaus ;
Driver, Jon ;
Rothwell, John C. .
EXPERIMENTAL BRAIN RESEARCH, 2008, 191 (04) :383-402
[4]   Dorsal premotor cortex exerts state-dependent causal influences on activity in contralateral primary motor and dorsal premotor cortex [J].
Bestmann, Sven ;
Swayne, Orlando ;
Blankenburg, Felix ;
Ruff, Christian C. ;
Haggard, Patrick ;
Weiskopf, Nikolaus ;
Josephs, Oliver ;
Driver, Jon ;
Rothwell, John C. ;
Ward, Nick S. .
CEREBRAL CORTEX, 2008, 18 (06) :1281-1291
[5]   Interhemispheric Effect of Parietal TMS on Somatosensory Response Confirmed Directly with Concurrent TMS-fMRI [J].
Blankenburg, Felix ;
Ruff, Christian C. ;
Bestmann, Sven ;
Bjoertomt, Otto ;
Eshel, Neir ;
Josephs, Oliver ;
Weiskopf, Nikolaus ;
Driver, Jon .
JOURNAL OF NEUROSCIENCE, 2008, 28 (49) :13202-13208
[6]   A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI [J].
Bohning, DE ;
Denslow, S ;
Bohning, PA ;
Walker, JA ;
George, MS .
CLINICAL NEUROPHYSIOLOGY, 2003, 114 (11) :2210-2219
[7]   Echoplanar BOLD fMRI of brain activation induced by concurrent transcranial magnetic stimulation [J].
Bohning, DE ;
Shastri, A ;
Nahas, Z ;
Lorberbaum, JP ;
Andersen, SW ;
Dannels, WR ;
Haxthausen, EU ;
Vincent, DJ ;
George, MS .
INVESTIGATIVE RADIOLOGY, 1998, 33 (06) :336-340
[8]  
BUNGERT A, 2008, P 16 ANN M ISMRM TOR
[9]  
Frackowiak R.S.J., 2003, HUMAN BRAIN FUNCTION, V2nd
[10]   An approach to MRI-based dosimetry for transcranial magnetic stimulation [J].
Hernandez-Garcia, Luis ;
Lee, Sangwoo ;
Grissom, William .
NEUROIMAGE, 2007, 36 (04) :1171-1178