Effects of argon ion irradiation on the microstructures and physical properties of carbon fibers

被引:13
作者
Oku, T
Kurumada, A
Kawamata, K
Inagaki, M
机构
[1] Ibaraki Univ, Univ Air, Ibaraki Study Ctr, Ibaraki 3100056, Japan
[2] Ibaraki Univ, Fac Engn, Ibaraki 3168511, Japan
[3] Aichi Inst Technol, Toyota 4700392, Japan
关键词
D O I
10.1016/S0022-3115(02)00809-7
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Eight kinds of carbon fibers with different microstructures have been exposed to argon ion implantation at 175 MeV - 1 muA for 399 min using AVF cyclotron. Takasaki Radiation Chemistry Research Establishment, JAERI. After ion irradiation changes in diameters and cross-sectional areas of carbon fibers were determined by scanning electron microscopy. Tensile properties were measured before and after ion irradiation. As a result, the diameter generally tended to decrease after ion irradiation, except for the carbon fiber with the dual microstructure that has two directions (radial and circumferential) of basal planes in the cross-section of the fiber. Tensile strength decreased after ion irradiation. The decrease in tensile strength suggests that changes in axial microstructures due to ion irradiation give an influence on the mechanical properties of the fibers. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:242 / 245
页数:4
相关论文
共 9 条
  • [1] Inagaki M., 1991, TANSO, V147, P57
  • [2] IWASHITA N, 1991, TANSO, V149, P204
  • [3] KELLY BT, 1981, PHYSICS GRAPHITE APP
  • [4] NEUTRON-IRRADIATION EFFECT ON THE THERMAL-CONDUCTIVITY AND DIMENSIONAL CHANGE OF GRAPHITE MATERIALS
    MARUYAMA, T
    HARAYAMA, M
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1992, 195 (1-2) : 44 - 50
  • [5] Microstructure of mesophase pitch-based carbon fiber and its control
    Mochida, I
    Yoon, SH
    Takano, N
    Fortin, F
    Korai, Y
    Yokogawa, K
    [J]. CARBON, 1996, 34 (08) : 941 - 956
  • [6] Oku T, 1997, SCI REP RES TOHOKU A, V45, P63
  • [7] OKU T, 1999, TANSO 1999, V190, P262
  • [8] TANABE Y, 1991, TANSO 1991, V147, P66
  • [9] ZIEGLER JF, 1995, TRIM VERSION 95 4