Analysis of petrol and diesel vapour and vehicle engine exhaust gases using selected ion flow tube mass spectrometry

被引:45
作者
Smith, D
Cheng, P
Spanel, P
机构
[1] Keele Univ, Postgrad Med Sch, Ctr Sci & Technol Med, Stoke On Trent ST4 7QB, Staffs, England
[2] Acad Sinica, Anhui Inst Opt & Fine Mech, Hefei, Anhui, Peoples R China
[3] Acad Sci Czech Republ, J Heyrovsky Inst Phys Chem, V Cermak Lab, CR-18223 Prague 8, Czech Republic
关键词
D O I
10.1002/rcm.691
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have used selected ion flow tube mass spectrometry (SIFT-MS) to analyse the vapours emitted by petrol and diesel fuels and the exhaust gases from petrol (spark ignition) and diesel (compression ignition) engine vehicles fitted with catalytic converters. Only those components of these media that have significant vapour pressures at ambient temperatures were analysed and thus particulates were obviously not detected. These media have been analysed using the full scope of SIFT-MS, i.e., with the three available precursor ions H3O+, NO+ and O-2(+). The combination of the H3O+ and NO+ analyses is seen to be essential to distinguish between different product ions at the same mass-to-charge ratio (m/z) especially in identifying aldehydes in the exhaust gases. The O-2(+) precursor ions are used to detect and quantify the large amount of nitric oxide present in the exhaust gases from both engine types. The petrol and diesel vapours consist almost exclusively of aliphatic alkanes, alkenes and alkynes (and dienes) and aromatic hydrocarbons. Some of these compounds appear in the exhaust gases together with several aldehydes, viz. formaldehyde, acetaldehyde, pentanal, pentenal (acrolein), butenal, and also methanol and ethanol. Acetone, nitric oxide and ammonia are also present, acetone and nitric oxide being much more abundant in the diesel exhaust gas than in the petrol exhaust gas. These data were obtained from samples collected into pre-evacuated stainless steel vessels. Trapping of the volatile compounds from the gas samples is not required and analysis was completed a few minutes later. All the above compounds are detected simultaneously, which demonstrates the value of SIFT-MS in this area of research. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:1124 / 1134
页数:11
相关论文
共 55 条
[1]  
Abdel-Rahman AA, 1998, INT J ENERG RES, V22, P483, DOI 10.1002/(SICI)1099-114X(199805)22:6<483::AID-ER377>3.0.CO
[2]  
2-Z
[3]   Dynamic modeling of a three-way catalyst for SI engine exhaust emission control [J].
Brandt, EP ;
Wang, YY ;
Grizzle, JW .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2000, 8 (05) :767-776
[4]   Quantitative analysis of ammonia on the breath of patients in end-stage renal failure [J].
Davies, S ;
Spanel, P ;
Smith, D .
KIDNEY INTERNATIONAL, 1997, 52 (01) :223-228
[5]   A new 'online' method to measure increased exhaled isoprene in end-stage renal failure [J].
Davies, S ;
Spanel, P ;
Smith, D .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (04) :836-839
[6]   Assessment of rumen processes by selected-lon-flow-tube mass spectrometric analysis of rumen gases [J].
Dewhurst, RJ ;
Evans, RT ;
Mottram, TT ;
Spanel, P ;
Smith, D .
JOURNAL OF DAIRY SCIENCE, 2001, 84 (06) :1438-1444
[7]  
DOLBER W, 1983, J CHEM PHYS, V79, P1543
[8]  
Fleming DM, 2001, BRIT J GEN PRACT, V51, P638
[9]  
GLASER RA, 1990, AM IND HYG ASSOC J, V51, P139, DOI 10.1202/0002-8894(1990)051<0139:COTSAA>2.0.CO
[10]  
2