A comparison of ELISA and flow micro sphere-based assays for quantification of immunoglobulins

被引:63
作者
Dasso, J
Lee, J
Bach, H
Mage, RG
机构
[1] NIAID, Immunol Lab, NIH, Bethesda, MD 20892 USA
[2] Childrens Natl Med Ctr, Washington, DC 20010 USA
关键词
ELISA; flow cytometry; multiplex assay; FlowMetrix (TM); fecal immunoglobulins;
D O I
10.1016/S0022-1759(02)00028-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automated microsphere-based flow cytometric assay (FlowMetrix(TM) system) was compared with a conventional enzyme-linked immunosorbent assay (ELISA) for quantifying Ig classes in serum and stool samples. The reproducibility of the process of coupling capture antibodies to microspheres was tested, The use of independently coupled microspheres did not increase the variation of assay results relative to using the same bead set in repeated assays. However, it is necessary to ensure quality control of the coupling process since slight variations in the coupling procedures can profoundly affect the density of capture reagents coupled to the microspheres and consequently adversely affect assay precision. Although the ELISA was more sensitive and did not have the problems with instrument performance encountered with the FlowMetrix(TM) assay, the latter was more reproducible, had a greater dynamic range of measurement, and took considerably less preparation time than the ELISA. Greater reproducibility is especially important for measurement of fecal Ig. which is typically highly variable. Thus, in addition to its multi-analyte capability, the FlowMetrix(TM) assay system has definite advantages over a conventional ELISA. Mechanical problems such as microspheres settling to the bottom of wells during analysis by an automated plate reader will likely be overcome, and sensitivity improved as this technology develops.
引用
收藏
页码:23 / 33
页数:11
相关论文
共 17 条
[1]  
Åhrén C, 1998, INFECT IMMUN, V66, P3311
[2]  
Bellisario R, 2000, CLIN CHEM, V46, P1422
[3]   Simultaneous measurement of antibodies to three HIV-1 antigens in newborn dried blood-spot specimens using a multiplexed microsphere-based immunoassay [J].
Bellisario, R ;
Colinas, RJ ;
Pass, KA .
EARLY HUMAN DEVELOPMENT, 2001, 64 (01) :21-25
[4]   Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay [J].
Carson, RT ;
Vignali, DAA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 227 (1-2) :41-52
[5]   A microsphere-based assay for multiplexed single nucleotide polymorphism analysis using single base chain extension [J].
Chen, JW ;
Iannone, MA ;
Li, MS ;
Taylor, JD ;
Rivers, P ;
Nelsen, AJ ;
Slentz-Kesler, KA ;
Roses, A ;
Weiner, MP .
GENOME RESEARCH, 2000, 10 (04) :549-557
[6]  
Fitzgerald DA, 2001, SCIENTIST, V15, P25
[7]  
Fulton RJ, 1997, CLIN CHEM, V43, P1749
[8]  
Gordon RF, 1997, CLIN CHEM, V43, P1799
[9]  
Kettman JR, 1998, CYTOMETRY, V33, P234, DOI 10.1002/(SICI)1097-0320(19981001)33:2<234::AID-CYTO19>3.0.CO
[10]  
2-V