Coupling CFD and human body thermoregulation model for the assessment of personalized ventilation

被引:48
作者
Gao, NP [1 ]
Niu, JL
Zhang, H
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
[2] Univ Calif Berkeley, Ctr Environm Design Res, Berkeley, CA 94720 USA
来源
HVAC&R RESEARCH | 2006年 / 12卷 / 03期
关键词
D O I
10.1080/10789669.2006.10391191
中图分类号
O414.1 [热力学];
学科分类号
摘要
Personalized ventilation has great potential to improve inhaled air quality and to accommodate individual thermal preferences. In order to quantify these perceived benefits, a numerical method has been developed. In this method, a numerical thermal manikin (NTM), with the real geometry of a human body, is obtained by employing a laser scanning technique. When placed in a virtual environment, the thermal interactions with the environment are calculated using computational fluid dynamics (CFD). By iteration, the calculated air velocity near the body surface is fed into a sophisticated thermoregulation model developed at the University of California, Berkeley, so that the local thermal comfort in a non-uniform environment created by personalized air (PA) is rigorously investigated. In this paper, the performances of three different PV systems are investigated, namely, the desk-edge-based PV, PV using a movable panel (MP), and chair-based PV. The results exhibit reasonable agreement with the experimental measurements. The three types of PV are all able to lower human exposure to ambient room pollutants and bring a "cool head" thermal condition favorable for thermal comfort. The present work illustrates that in the development of localized personal environmental control systems, an NTM coupled with a human-body thermal regulation model is a useful tool for visualizing thermal comfort and ventilation effectiveness.
引用
收藏
页码:497 / 518
页数:22
相关论文
共 40 条
[1]  
[Anonymous], 2000, AIR DISTRIBUTION ROO
[2]  
*ASHRAE, 2001, 2001 ASHRAE HDB FUND, pCH8
[3]  
BAUMAN FS, 2001, ASHRAE J, V43, P20
[4]  
Bolashikov ZD., 2003, P ISIAQ SINGAPORE 7, P850
[5]  
CURRLE J, 1997, 970529 SAE, P806
[6]   Convective and radiative heat transfer coefficients for individual human body segments [J].
deDear, RJ ;
Arens, E ;
Hui, Z ;
Oguro, M .
INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1997, 40 (03) :141-156
[7]   Indoor air quality in the 21st century: Search for excellence [J].
Fanger, PO .
INDOOR AIR, 2000, 10 (02) :68-73
[8]  
Fanger PO, 1970, THERMAL COMFORT
[9]   Ventilation efficiencies and thermal comfort results of a desk-edge-mounted task ventilation system [J].
Faulkner, D ;
Fisk, WJ ;
Sullivan, DP ;
Lee, SM .
INDOOR AIR, 2004, 14 :92-97
[10]  
FAULKNER D, 1993, ASHRAE TRAN, V99, P750