A calibration method free of optimism factor number selection for automated multivariate analysis. Experimental and theoretical study

被引:83
作者
Xu, LA [1 ]
Schechter, I [1 ]
机构
[1] TECHNION ISRAEL INST TECHNOL, DEPT CHEM, IL-32000 HAIFA, ISRAEL
关键词
D O I
10.1021/ac970402y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several analytical applications of multivariate calibration methods require human decisions, the most difficult being the number of factors involved, Thus, eliminating the optimum factor number may contribute to the improvement of automatic calibration processes. We propose a factor analysis method that does not need the factor number, It is particularly suitable for indited calibration of a system under indirect observation. The algorithm is based on composing a subspace excluding the contribution from the component of interest and calculating its net analyte signal through an orthogonal projection to an orthogonal space, This method is applicable as long as the spectral vector dimension (i.e., the number of data points) is larger than the calibration set size, This condition readily satisfied in spectroscopic analysis, The relevant effects, including the effect of the spectral vector dimension and of the calibration set size upon prediction errors, have been investigated using extensive computer simulation, The algorithm has been exemplified by a successful application to the predictions of ethanol concentration and of octane number of gasoline samples using near-IR spectra. In this example of an indirect calibration, the proposed method, which requires no information on optimum factor number, is of particular importance, In most cases, the results obtained by this method are similar to those of the traditional PCR; however, this method does not fail when the optimal model cannot be correctly determined by automatic procedures.
引用
收藏
页码:3722 / 3730
页数:9
相关论文
共 39 条
[1]  
[Anonymous], 1988, J CHEMOM, DOI DOI 10.1002/CEM.1180020203
[2]  
[Anonymous], J CHEMOMETR
[3]   THEORY OF ANALYTICAL-CHEMISTRY [J].
BOOKSH, KS ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :A782-A791
[4]   Chemical systems under indirect observation: Latent properties and chemometrics [J].
Brown, SD .
APPLIED SPECTROSCOPY, 1995, 49 (12) :A14-A31
[5]   SCREE TEST FOR NUMBER OF FACTORS [J].
CATTELL, RB .
MULTIVARIATE BEHAVIORAL RESEARCH, 1966, 1 (02) :245-276
[6]   DETERMINATION OF OCTANE NUMBERS AND REID VAPOR-PRESSURE OF COMMERCIAL PETROLEUM FUELS USING FT-RAMAN SPECTROSCOPY AND PARTIAL LEAST-SQUARES REGRESSION-ANALYSIS [J].
COOPER, JB ;
WISE, KL ;
GROVES, J ;
WELCH, WT .
ANALYTICAL CHEMISTRY, 1995, 67 (22) :4096-4100
[7]   IMPROVING RELIABILITY OF FACTOR-ANALYSIS OF CHEMICAL DATA BY UTILIZING MEASURED ANALYTICAL UNCERTAINTY [J].
DUEWER, DL ;
KOWALSKI, BR ;
FASCHING, JL .
ANALYTICAL CHEMISTRY, 1976, 48 (13) :2002-2010
[8]   SELECTION OF ANALYTICAL WAVELENGTHS FOR MULTICOMPONENT SPECTROPHOTOMETRIC DETERMINATIONS [J].
FRANS, SD ;
HARRIS, JM .
ANALYTICAL CHEMISTRY, 1985, 57 (13) :2680-2684
[9]   STATISTICAL ASSESSMENT OF A NEW CRITERION FOR SELECTING THE NUMBER OF FACTORS IN FACTOR-ANALYSIS [J].
GONZALEZ, AG ;
GONZALEZARJONA, D .
ANALYTICA CHIMICA ACTA, 1995, 314 (03) :251-252
[10]   HOLMES - A PROGRAM FOR TARGET FACTOR-ANALYSIS [J].
GONZALEZARJONA, D ;
MEJIAS, JA ;
GONZALEZ, AG .
ANALYTICA CHIMICA ACTA, 1994, 295 (1-2) :119-125