Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data

被引:111
作者
Grass, M [1 ]
Koppe, R [1 ]
Klotz, E [1 ]
Proksa, R [1 ]
Kuhn, MH [1 ]
Aerts, H [1 ]
Op de Beek, J [1 ]
Kemkers, R [1 ]
机构
[1] Philips Res Labs, Div Tech Syst, D-22335 Hamburg, Germany
关键词
cerebral aneurysm; 3D bone reconstruction; C-arm system; high contrast objects;
D O I
10.1016/S0895-6111(99)00028-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The reconstruction of three-dimensional (3D) objects from D X-ray cone-beam projections using a circular source path is most commonly done with an algorithm according to Feldkamp et al. [Feldkamp LA, Davis LC, Kress JW. Practical cone-beam algorithms. J Opt Soc Am A 1984;6:612-619]. An adaptation of this so-called Feldkamp method to cone-beam projections acquired with a C-arm system is presented here. In a phantom study, reconstruction results obtained along real source-detector trajectories of a C-arm system are compared to reconstruction results obtained from projections acquired from a full-circular trajectory and from one consisting of two full orthogonal circles, which fulfills Tuy's sufficiency condition. The straightforward application of Feldkamp's method adapted to projection data obtained with a C-ann system illustrates the 3D imaging potential of image intensifier based cone-beam computed tomography. Reconstruction results from projection data of different patients acquired with a motorized C-arm system such as vessel structures filled with contrast agent and bones on presented. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:311 / 321
页数:11
相关论文
共 17 条
  • [1] CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS
    CHO, PS
    JOHNSON, RH
    GRIFFIN, TW
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11) : 1863 - 1883
  • [2] DANIELSSON PE, 1996, LITHISYR1847
  • [3] A CONE-BEAM RECONSTRUCTION ALGORITHM USING SHIFT-VARIANT FILTERING AND CONE-BEAM BACKPROJECTION
    DEFRISE, M
    CLACK, R
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) : 186 - 195
  • [4] Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion
    Fahrig, R
    Moreau, M
    Holdsworth, DW
    [J]. MEDICAL PHYSICS, 1997, 24 (07) : 1097 - 1106
  • [5] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [6] GRANGEAT P, 1991, LECT NOTES MATH
  • [7] Jacobson C., 1996, THESIS
  • [8] JOHNSON RH, 1997, INT M FULL 3 DIM IM
  • [9] KEMKERS R, 1998, P CAR 98 TOK
  • [10] KOPPE R, 1996, P CAR 96 PAR