Simultaneous quantification of fexofenadine and pseudoephedrine in human plasma by liquid chromatography/tandem mass spectrometry with electrospray ionization: method development, validation and application to a clinical study

被引:24
作者
Nirogi, Ramakrishna V. S. [1 ]
Kandikere, Vishwottam N. [1 ]
Shukla, Manoj [1 ]
Mudigonda, Koteshwara [1 ]
Maurya, Santosh [1 ]
Komarneni, Prashanth [1 ]
机构
[1] Suven Life Sci Ltd, Hyderabad 500034, Andhra Pradesh, India
关键词
D O I
10.1002/rcm.2701
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
To support the pharmacokinetic and bioavailability study of a once-daily fexofenadine/pseudoephedrine combination, a high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (HPLC/ESI-MS/MS) method for the simultaneous quantification of fexofenadine and pseudoephedrine was developed and validated with 500 mu L human plasma using mosapride as an internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 502/466 for fexofenadine, m/z 166/148 for pseuoephedrine and m/z 422/198 for the IS. The method exhibited linear dynamic ranges of 1-500 ng/ mL and 2-1000 ng/mL for fexofenadine and pseudoephedrine, respectively, in human plasma. The lower limits of quantification were 1 and 2 ng/mL with a relative standard deviation of less than 10% for fexofenadine and pseudoephedrine, respectively. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The total chromatographic run time was 2 min and more than 400 human plasma samples could be analyzed in one day by running the system overnight. The method is precise and sensitive enough for its intended purpose. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:3030 / 3038
页数:9
相关论文
共 25 条
[1]
SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF PSEUDOEPHEDRINE IN PLASMA AND URINE [J].
BRENDEL, E ;
MEINEKE, I ;
HENNE, EM ;
ZSCHUNKE, M ;
DEMEY, C .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 426 (02) :406-411
[2]
DETERMINATION OF TERFENADINE AND TERFENADINE ACID METABOLITE IN PLASMA USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
COUTANT, JE ;
WESTMARK, PA ;
NARDELLA, PA ;
WALTER, SM ;
OKERHOLM, RA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (01) :139-148
[3]
Cvetkovic M, 1999, DRUG METAB DISPOS, V27, P866
[4]
Fromm MF, 2000, INT J CLIN PHARM TH, V38, P69
[5]
Determination of fexofenadine in human plasma using 96-well solid phase extraction and HPLC with tandem mass spectrometric detection [J].
Fu, I ;
Woolf, EJ ;
Matuszewski, BK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (04) :837-846
[6]
Guo P, 1999, BIOMED CHROMATOGR, V13, P61, DOI 10.1002/(SICI)1099-0801(199902)13:1<61::AID-BMC819>3.0.CO
[7]
2-D
[8]
Automated trace enrichment for screening and/or determination of primary, secondary and tertiary amphetamines in biological samples by liquid chromatography [J].
Herráez-Hernández, R ;
Campíns-Falcó, P .
ANALYST, 1999, 124 (03) :239-244
[9]
Hindmarch I., 2002, Clinical and Experimental Allergy Reviews, V2, P26, DOI 10.1046/j.1472-9725.2002.00031.x
[10]
Determination of fexofenadine in human plasma and urine by liquid chromatography-mass spectrometry [J].
Hofmann, U ;
Seiler, M ;
Drescher, S ;
Fromm, MF .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 766 (02) :227-233