Trace analysis of pesticide residues in water by high-speed narrow-bore capillary gas chromatography-mass spectrometry with programmable temperature vaporizer

被引:41
作者
Hada, M
Takino, M
Yamagami, T
Daishima, S
Yamaguchi, K
机构
[1] Yokogawa Analyt Syst Inc, Yodogawa Ku, Osaka 5320033, Japan
[2] Yokogawa Analyt Syst Inc, Musashino, Tokyo 1800006, Japan
关键词
large-volume injection; programmable temperature vaporizer; narrow-bore columns; pesticides;
D O I
10.1016/S0021-9673(00)00076-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for the rapid trace analysis of 17 residual pesticides in water by narrow-bore capillary (I.D. 100 mu m) gas chromatography-mass spectrometry (GC-MS) using a programmable temperature vaporizer (PTV) was discussed. The method consisted of a large-volume injection (40 mu l) by a PTV, high-speed analysis using a narrow-bore capillary column and MS detection. The PTV with solvent vent mode was very useful for large-volume injection into a narrow-bore capillary column because the injected solvent volume could be reduced to less than 2 mu l. The analysis time was 8.5 min [less than 50% of the analysis time using conventional columns (I.D. 250 mu m)]. A 10-ml volume of river water was extracted by dichloromethane (4 ml), and then the extract was condensed to 1 ml. This extract was analyzed. Mean recoveries for river water spiked at 100 pg/ml ranged from 83.4 to 96.7%. The limit of detections of the 17 pesticides ranged from 1 to 100 pg/ml. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:81 / 90
页数:10
相关论文
共 12 条
[1]   Instrumentation and applications of fast high-resolution capillary gas chromatography [J].
David, F ;
Gere, DR ;
Scanlan, F ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :309-319
[2]  
Desty D. H, 1962, GAS CHROMATOGRAPHY, P105
[3]   Programmed temperature vaporisers-based large volume injection in capillary gas chromatography [J].
Engewald, W ;
Teske, J ;
Efer, J .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :143-161
[4]   PEAK BROADENING OR SPLITTING CAUSED BY SOLVENT FLOODING AFTER SPLITLESS OR COLD ON-COLUMN INJECTION IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1981, 213 (01) :3-14
[5]   SOLVENT EFFECTS IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV) :225-232
[6]  
LIESHOUT MV, 1998, J HIGH RES CHROMATOG, V21, P583
[7]  
MCMILLIN R, 1999, AT PROCESS, V4, P48
[8]  
PLOTCZYK LL, 1982, J CHROMATOGR, V244, P185
[9]   VARIABLES AFFECTING THE INTRODUCTION OF LARGE-SAMPLE VOLUMES IN CAPILLARY GAS-CHROMATOGRAPHY USING A PROGRAMMED-TEMPERATURE VAPORIZER [J].
SENORANS, FJ ;
TABERA, J ;
VILLEN, J ;
HERRAIZ, M ;
REGLERO, G .
JOURNAL OF CHROMATOGRAPHY, 1993, 648 (02) :407-414
[10]  
SNIJDERS HM, 1994, P 16 INT S CAP CHROM, P1137