Determination of oxycodone and its metabolite, noroxycodone, in human plasma by HPLC with post-column chemiluminescence detection using electrogenerated tris(2,2′-bipyridyl)ruthenium(III)

被引:8
作者
Gemba, Y [1 ]
Konishi, M [1 ]
Sakata, T [1 ]
Okabayashi, Y [1 ]
机构
[1] Shionogi & Co Ltd, Shionogi Res Labs, Fukushima Ku, Osaka 5530002, Japan
关键词
oxycodone; noroxycodone; post-column chemiluminescence; human plasma;
D O I
10.1081/JLC-120034095
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive high performance liquid chromatography (HPLC) method with post-column chemiluminescence detection was developed for the simultaneous determination of oxycodone (OXC) and its metabolite, noroxycodone (NOC), in human plasma. Sample preparation for human plasma was performed by means of solid extraction with Sep-Pak Vac Cl8 (100 mg/mL). Separation was performed by reversed-phase HPLC using a 5-mum Develosil ODS-HG-5 column (150 mm x 4.6 mm) and a mobile phase consisting of a mixture of 0.1 mol/L phosphate buffer (pH 2.6) containing 5 mmol/L sodium dodecylsulfate and methanol (53: 47, v/v). Quantitation was performed by the measurement of chemiluminescence using electrogenerated tris(2,2'-bipyridyl)ruthenium(III). The lower and upper limits of quantitation for OXC and NOC were 0.5-250 ng/mL and 1-500 ng/mL, respectively. The calibration curve for this assay showed good linearity for the concentration range of 0.5-50 ng/mL for OXC and 1-100 ng/mL for NOC. Recoveries of the studied compounds were excellent at the individual assay ranges (102.9-108.7%), and validation of the assay gave results that were satisfactory in terms of within-run or between-run precision (1.9-11.9% as RSD) and accuracy (-13.5% to + 9.2% as bias). Stability studies showed that OXC and NOC were stable in assay solutions for at least 6 days at 4degreesC storage in the autosampler. OXC and NOC were also stable in human plasma for at least 48 hr at room temperature, for at least 8 months at -20degreesC and after five repeated freeze-thaw cycles. Furthermore, OXC and NOC were stable in human whole blood for up to 5 days at 4degreesC and for up to 5 hr at room temperature. This system was applied to the clinical study of cancer patients after single oral administration doses of controlled-released tablets of OXC hydrochloride. Consequently, this method should serve as a useful tool for pharmacokinetic studies of OXC and NOC.
引用
收藏
页码:1611 / 1626
页数:16
相关论文
共 18 条
[1]  
BEAVER WT, 1978, J PHARMACOL EXP THER, V207, P101
[2]   Peak fronting in reversed-phase high-performance liquid chromatography:: a study of the chromatographic behavior of oxycodone hydrochloride [J].
Broglé, K ;
Ornaf, RM ;
Wu, D ;
Palermo, PJ .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (05) :669-678
[3]   Rapid determination of selected drugs of abuse in human plasma using a monolithic silica HPLC column and solid phase extraction [J].
Caufield, WV ;
Stewart, JT .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2002, 25 (19) :2977-2998
[4]   A rapid and sensitive high-performance liquid chromatography-electrospray ionization-triple quadrupole mass spectrometry method for the quantitation of oxycodone in human plasma [J].
Dawson, M ;
Fryirs, B ;
Kelly, T ;
Keegan, J ;
Mather, LE .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (01) :40-44
[5]   Simultaneous determination of oxycodone and noroxycodone in dog plasma and urine by HPLC, with post-column chemiluminescence detection using electrogenerated tris(2,2′-bipyridyl) ruthenium(III) [J].
Gemba, Y ;
Hashimoto, H ;
Konishi, M .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2004, 27 (05) :843-862
[6]   Pharmacokinetic-pharmacodynamic relationships of controlled-release oxycodone [J].
Kaiko, RF ;
Benziger, DP ;
Fitzmartin, RD ;
Burke, BE ;
Reder, RF ;
Goldenheim, PD .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1996, 59 (01) :52-61
[7]   MORPHINE AND OXYCODONE HYDROCHLORIDE IN THE MANAGEMENT OF CANCER PAIN [J].
KALSO, E ;
VAINIO, A .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1990, 47 (05) :639-646
[8]   NANOGRAM LEVEL QUANTITATION OF OXYCODONE IN HUMAN PLASMA BY CAPILLARY GAS-CHROMATOGRAPHY USING NITROGEN PHOSPHORUS SELECTIVE DETECTION [J].
KAPIL, RP ;
PADOVANI, PK ;
KING, SYP ;
LAM, GN .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 577 (02) :283-287
[9]   A review of recent trends in analytical applications of electrogenerated chemiluminescence [J].
Knight, AW .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (01) :47-62
[10]   Relationship between structural attributes and observed electrogenerated chemiluminescence (ECL) activity of tertiary amines as potential analytes for the tris(2,2-bipyridine)ruthenium(II) ECL reaction - A review [J].
Knight, AW ;
Greenway, GM .
ANALYST, 1996, 121 (11) :R101-R106