Reperfusion response changes induced by repeated, sustained contractions in normal human masseter muscle

被引:8
作者
Aizawa, S [1 ]
Tsukiyama, Y
Koyano, K
Clark, GT
机构
[1] Kyushu Univ, Grad Sch Dent Sci, Dept Oral Rehabil, Sect Removable Prosthodont, Fukuoka 8128582, Japan
[2] Univ Calif Los Angeles, Sch Dent, Sect Oral Med & Orofacial Pain, Los Angeles, CA 90095 USA
关键词
endurance contraction; intramuscular blood volume; masseter muscle; near-infrared spectroscopy; post-contraction vasodilation;
D O I
10.1016/S0003-9969(02)00037-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose was to evaluate the intramuscular reperfusion response characteristics associated with repeated isometric contractions in normal human masseter. Intramuscular blood volume was quantified with a near-infrared spectroscopic device that measured the total haemoglobin (Hb) concentration in the muscle. Electromyographic (EMG) activity from the masseter and total bite forces were also recorded. Sixteen healthy volunteers, eight females and eight males, without masticatory muscle pain participated. They were asked first to clench their teeth for as long as possible at 50% of their maximum voluntary contraction (MVC). This was followed by a 60 s rest and then immediately by a standard clenching task (50% MVC for 30 s) and a 60 s recovery period, immediately after which they were asked to repeat exactly the same procedure, with a final 5 min recovery period after the second 30 s contraction. Bite force, EMG and Hb concentration were measured continuously and the duration of the two endurance tasks and the amplitudes of all recorded signals were compared (first trial versus second trial). Specifically, the difference between the lowest Hb (trough) seen during the standardised 30 s contractions and the highest (peak) seen just after them was assessed. The trough-to-peak difference in Hb concentration of the second standard contraction task was significantly smaller than that of the first standard task (P < 0.05, paired t-test). These data show that with sustained effort the post-contraction vasodilatory reperfusion responses of the human masseter are diminished, suggesting a progressive desensitisation of the vasodilatory system. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:537 / 543
页数:7
相关论文
共 15 条
[1]   Haemodynamic responses in chronically painful, human trapezius muscle to cold pressor stimulation [J].
Acero, CO ;
Kuboki, T ;
Maekawa, K ;
Yamashita, A ;
Clark, GT .
ARCHIVES OF ORAL BIOLOGY, 1999, 44 (10) :805-812
[2]  
CHANCE B, 1992, AM J PHYSIOL-CELL PH, V262, P766
[3]  
Clark G T, 1993, Adv Dent Res, V7, P97
[4]   JAW PAIN AND STIFFNESS LEVELS AFTER REPEATED MAXIMUM VOLUNTARY CLENCHING [J].
CLARK, GT ;
JOW, RW ;
LEE, JJ .
JOURNAL OF DENTAL RESEARCH, 1989, 68 (01) :69-71
[5]   Haemodynamic changes induced by submaximal isometric contraction in painful and non-painful human masseter using near-infra-red spectroscopy [J].
Delcanho, RE ;
Kim, YJ ;
Clark, GT .
ARCHIVES OF ORAL BIOLOGY, 1996, 41 (06) :585-596
[6]  
Goulet JP, 1998, J OROFAC PAIN, V12, P17
[7]   MECHANICAL INFLUENCES ON LONG-LASTING HUMAN-MUSCLE FATIGUE AND DELAYED-ONSET PAIN [J].
JONES, DA ;
NEWHAM, DJ ;
TORGAN, C .
JOURNAL OF PHYSIOLOGY-LONDON, 1989, 412 :415-427
[8]   ENDURANCE AND RECOVERY FROM A SUSTAINED ISOMETRIC CONTRACTION IN HUMAN JAW-ELEVATING MUSCLES [J].
JOW, RW ;
CLARK, GT .
ARCHIVES OF ORAL BIOLOGY, 1989, 34 (11) :857-862
[9]   Haemodynamic changes in human masseter and temporalis muscles induced by different levels of isometric contraction [J].
Kim, YJ ;
Kuboki, T ;
Tsukiyama, Y ;
Koyano, K ;
Clark, GT .
ARCHIVES OF ORAL BIOLOGY, 1999, 44 (08) :641-650
[10]   Correlation of the near-infrared spectroscopy signals with signal intensity in T2-weighted magnetic resonance imaging of the human masseter muscle [J].
Kuboki, T ;
Suzuki, K ;
Maekawa, K ;
Inoue-Minakuchi, M ;
Acero, CO ;
Yanagi, Y ;
Wakasa, T ;
Kishi, K ;
Yatani, H ;
Clark, GT .
ARCHIVES OF ORAL BIOLOGY, 2001, 46 (08) :721-727