Assessment of trabecular bone structure of the calcaneus using multi-detector CT: Correlation with microCT and biomechanical testing

被引:58
作者
Diederichs, Gerd [1 ,2 ]
Link, Thomas M. [1 ]
Kentenich, Marie [1 ,2 ]
Schwieger, Karsten [3 ]
Huber, Markus B. [1 ]
Burghardt, Andrew J. [1 ]
Majumdar, Sharmila [1 ]
Rogalla, Patrik [2 ]
Issever, Ahi S. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, Musculoskeletal & Quantitat Imaging Res Grp, San Francisco, CA 94107 USA
[2] Charite Univ Med Berlin, Dept Radiol, D-10117 Berlin, Germany
[3] AO Res Inst, Res Serv Grp, CH-7270 Davos, Switzerland
关键词
CT; Calcaneus; Bone quality; Bone structure; Osteoporosis; HIGH-RESOLUTION MRI; SPIRAL COMPUTED-TOMOGRAPHY; STRENGTH IN-VITRO; TEXTURE ANALYSIS; MINERAL DENSITY; PROXIMAL FEMUR; IMAGE-ANALYSIS; FRACTURE RISK; VERTEBRAL MICROSTRUCTURE; SPATIAL-RESOLUTION;
D O I
10.1016/j.bone.2009.01.372
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The prediction of bone strength can be improved when determining bone mineral density (BMD) in combination with measures of trabecular microarchitecture. The goal of this study was to assess parameters of trabecular bone structure and texture of the calcaneus by clinical multi-detector row computed tomography (MDCT) in an experimental in situ setup and to correlate these parameters with microCT (mu CT) and biomechanical testing. Thirty calcanei in 15 intact cadavers were scanned using three different protocols on a 64-slice MDCT scanner with an in-plane pixel size of 208 pm and 500 mu m slice thickness. Bone cores were harvested from each specimen and mu CT images with a voxel size of 16 pm were obtained. After image coregistration, trabecular bone structure and texture were evaluated in identical regions on the MDCT images. After data acquisition, uniaxial compression testing was performed. Significant correlations between MDCT- and pC7-derived measures of bone volume fraction (BV/TV), trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp) were found (range, R(2) = 0.19-0.65, p<0.01 or 0.05). The MDCT-derived parameters of volumetric BMD, app. BV/TV, app. Tb.Th and app. Tb.Sp were capable of predicting 60%, 63%, 53% and 25% of the variation in bone strength (p<0.01). When combining those measures with one additional texture index (either GLCM, TOGLCM or MF.euler), prediction of mechanical competence was significantly improved to 86%, 85%, 71% and 63% (p<0.01). In conclusion, this study showed the feasibility of trabecular microarchitecture assessment using MDCT in an experimental setup simulating the clinical situation. Multivariate models of BMD OF structural parameters combined with texture indices improved prediction of bone strength significantly and might provide more reliable estimates of fracture risk in patients. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:976 / 983
页数:8
相关论文
共 39 条
[1]   Bone strength and its determinants [J].
Ammann, P ;
Rizzoli, R .
OSTEOPOROSIS INTERNATIONAL, 2003, 14 (Suppl 3) :S13-S18
[2]   EVALUATION OF TEXTURAL AND MULTIPOLARIZATION RADAR FEATURES FOR CROP CLASSIFICATION [J].
ANYS, H ;
HE, DC .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1995, 33 (05) :1170-1181
[3]   Analysis of trabecular bone structure with multidetector spiral computed tomography in a simulated soft-tissue environment [J].
Bauer, Jan S. ;
Link, Thomas M. ;
Burghardt, Andrew ;
Henning, Tobias D. ;
Mueller, Dirk ;
Majumdar, Sharmila ;
Prevrhal, Sven .
CALCIFIED TISSUE INTERNATIONAL, 2007, 80 (06) :366-373
[4]   Structural analysis of trabecular bone of the proximal femur using multislice computed tomography:: A comparison with dual x-ray absorptiometry for predicting biomechanical strength in vitro [J].
Bauer, JS ;
Kohlmann, S ;
Eckstein, F ;
Mueller, D ;
Lochmüller, EM ;
Link, T .
CALCIFIED TISSUE INTERNATIONAL, 2006, 78 (02) :78-89
[5]  
Bauer JS, 2004, ROFO-FORTSCHR RONTG, V176, P709, DOI 10.1055/s-2004-813079
[6]  
BOEHM H, 2006, ANAL TOPOLOGICAL PRO, P6144
[7]   Local 3D scaling properties for the analysis of trabecular bone extracted from high-resolution magnetic resonance imaging of human trabecular bone - Comparison with bone mineral density in the prediction of biomechanical strength in vitro [J].
Boehm, HF ;
Raeth, C ;
Monetti, RA ;
Mueller, D ;
Newitt, D ;
Majumdar, S ;
Rummeny, E ;
Morfill, G ;
Link, TM .
INVESTIGATIVE RADIOLOGY, 2003, 38 (05) :269-280
[8]   Relationship between computed tomographic image analysis and histomorphometry for microarchitectural characterization of human calcaneus [J].
Cortet, B ;
Chappard, D ;
Boutry, N ;
Dubois, P ;
Cotten, A ;
Marchandise, X .
CALCIFIED TISSUE INTERNATIONAL, 2004, 75 (01) :23-31
[9]   Computed tomography image analysis of the calcaneus in male osteoporosis [J].
Cortet, B ;
Dubois, P ;
Boutry, N ;
Palos, G ;
Cotten, A ;
Marchandise, X .
OSTEOPOROSIS INTERNATIONAL, 2002, 13 (01) :33-41
[10]   RISK-FACTORS FOR HIP FRACTURE IN WHITE WOMEN [J].
CUMMINGS, SR ;
NEVITT, MC ;
BROWNER, WS ;
STONE, K ;
FOX, KM ;
ENSRUD, KE ;
CAULEY, JC ;
BLACK, D ;
VOGT, TM .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (12) :767-773