Corneal and retinal temperatures under various ambient conditions: A model and experimental approach

被引:17
作者
Geiser, MH [1 ]
Bonvin, M [1 ]
Quibel, O [1 ]
机构
[1] HEVs, CH-1950 Sion, Switzerland
关键词
choroid; blood supply; temperature; model;
D O I
10.1055/s-2004-812878
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To determine the distribution of temperatures between the cornea and retina under various external conditions, such as illumination and external temperature, using a simplified heat exchange model. Materials and Methods: The human eye is modeled as a water sphere surrounded by different heat sources: choroidal and ciliary body blood flow, tears evaporation, metabolic activity, diffuse retinal illumination and external convection. Corneal and retinal temperatures are derived from this model using finite element theory applied to heat transport. Each of five subjects (28 +/- 10 years old) were placed in three different environments: -20degreesC, 20degreesC and 40degreesC. After 15 mn, their corneal temperatures were measured with an infrared camera. Corneal temperatures are compared with the values obtained from the model, assuming the same blood flow for all environments. Results: 1) Ciliary body and choroid contribute at least 20 times more than retina to the retinal temperature; 2) temperature increase of the retina due to illumination is negligible; 3) a 10% reduction of choroidal blood flow induces a corneal temperature decrease of 0.2degreesC at -20degreesC and <0.1degreesC at 20degreesC and 40degreesC. At normal choroidal blood flow, changes in ambient temperature have a negligible effect on retinal temperature. Measured corneal temperatures agreed with the values from the model: 26.4 +/- 0.9 versus 26.8degreesC, at -20degreesC and 36.2 +/- 0.5 versus 36.7 at 40degreesC. Conclusions: Our simplified eye model predicts in a satisfactory way measured corneal temperatures under very different conditions. Calculations show that changing external temperatures from -20 to + 40degreesC affects the retinal temperature by less than 1.8degreesC.
引用
收藏
页码:311 / 314
页数:4
相关论文
共 9 条
[1]  
[Anonymous], 1992, ADLERS PHYSL EYE
[2]   CHOROIDAL BLOOD-FLOW .1. OCULAR TISSUE TEMPERATURE AS A MEASURE OF FLOW [J].
AUKER, CR ;
PARVER, LM ;
DOYLE, T ;
CARPENTER, DO .
ARCHIVES OF OPHTHALMOLOGY, 1982, 100 (08) :1323-1326
[3]  
Bron AJ., 1997, WOLFFS ANATOMY EYE O, V8th
[4]   Activation of scleral cold thermoreceptors by temperature and blood flow changes [J].
Gallar, J ;
Acosta, MC ;
Belmonte, C .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (02) :697-705
[5]   Is corneal temperature correlated with blood-flow velocity in the ophthalmic artery? [J].
Gugleta, K ;
Orgül, S ;
Flammer, J .
CURRENT EYE RESEARCH, 1999, 19 (06) :496-501
[6]   Variability in the measurement of corneal temperature using a noncontact infrared thermometer [J].
Koçak, I ;
Orgül, S ;
Flammer, J .
OPHTHALMOLOGICA, 1999, 213 (06) :345-349
[7]   Posture changes and subfoveal choroidal blood flow [J].
Longo, A ;
Geiser, MH ;
Riva, CE .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (02) :546-551
[8]   DETERMINANTS OF CORNEAL TEMPERATURE [J].
MAPSTONE, R .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1968, 52 (10) :729-&
[9]   STATIC AND DYNAMIC INFRARED THERMOMETRY AND THERMOGRAPHY IN MELANOMAS OF THE CHOROID AND CONJUNCTIVA [J].
WITTIG, I ;
KOHLMANN, H ;
LOMMATZSCH, PK ;
KRUGER, L ;
HEROLD, H .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1992, 201 (05) :317-321