Separation and preconcentration by flow injection coupled to tungsten coil electrothermal atomic absorption spectrometry

被引:33
作者
Silva, MM
Krug, FJ
Oliveira, PV
Nobrega, JA
Reis, BF
Penteado, DAG
机构
[1] USP,CTR ENERGIA NUCL AGR,BR-13400970 PIRACICABA,SP,BRAZIL
[2] UFSCAR,DEPT QUIM,BR-13565905 SAO CARLOS,SP,BRAZIL
关键词
Chelex-100; electrothermal atomic absorption spectrometry; flow injection; lead; preconcentration; tungsten coil atomizer;
D O I
10.1016/S0584-8547(96)01536-4
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A flow injection system coupled to a tungsten coil electrothermal atomizer has been developed for on-line separation and preconcentration, using lead as a model element. The system utilizes three-way solenoid valves for sampling, buffering, washing and reconditioning solution management, and the resin column is inserted in the tip of the autosampler arm of a Varian GTA-96. The solenoid valves and tungsten coil power supply were controlled by a computer program written in Visual Basic, interfaced with the built-in Varian software. The system performance was tested by loading the resin column with the sample flowing at 3 ml min(-1) for 60 s. Elution was performed automatically by sampling 20 mu l of the eluent from a sample cup of the autosampler, and this aliquot was delivered into a 150 W tungsten coil. With Chelex-100 resin, the separation of concomitants was tested with lead in the presence of as much as 1000 mg l(-1) of Ca, Mg, Na or K. The model system presented an enrichment factor of 64 at a sampling rate of 30 samples per hour.
引用
收藏
页码:1925 / 1934
页数:10
相关论文
共 30 条
[1]   SPECIATION OF PARTS-PER-BILLION OF METAL-IONS USING SILICA AND C18-BONDED SILICA COLUMNS AND GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
ATALLAH, RH ;
CHRISTIAN, GD ;
NEVISSI, AE .
ANALYTICAL LETTERS, 1991, 24 (08) :1483-1502
[2]   DETERMINATION OF TRACE-METALS IN SEAWATER BY GRAPHITE-FURNACE ATOMIC-ABSORPTION FOLLOWING ONLINE SEPARATION AND PRECONCENTRATION [J].
AZEREDO, LC ;
STURGEON, RE ;
CURTIUS, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (01) :91-98
[3]   DESIGN OF A CONTINUOUS-FLOW 2-STEP EXTRACTION SAMPLE WORK-UP SYSTEM FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BACKSTROM, K ;
DANIELSSON, LG .
ANALYTICA CHIMICA ACTA, 1990, 232 (02) :301-315
[4]  
BACKSTROM K, 1988, ANAL CHEM, V60, P1354
[5]   FLOW-INJECTION THERMOSPRAY SAMPLE DEPOSITION FOR ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY [J].
BANK, PC ;
DELOOSVOLLEBREGT, MTC ;
DEGALAN, L .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (08) :983-987
[6]   FLOW-INJECTION THERMOSPRAY SAMPLE DEPOSITION FOR ELECTROTHERMAL ATOMIZATION-ATOMIC ABSORPTION SPECTROMETRY [J].
BANK, PC ;
DELOOSVOLLEBREGT, MTC ;
DEGALAN, L .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (06) :571-579
[7]   DESIGN AND EVALUATION OF AN ONLINE MICROCOLUMN PRE-CONCENTRATION TECHNIQUE FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BEINROHR, E ;
CAKRT, M ;
RAPTA, M ;
TARAPCI, P .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :1005-1007
[8]   SIMPLE LOW-COST TUNGSTEN-COIL ATOMIZER FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BERNDT, H ;
SCHALDACH, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :709-712
[9]   ANALYTICAL EVALUATION OF A TUNGSTEN COIL ATOMIZER FOR CADMIUM, LEAD, CHROMIUM, MANGANESE, NICKEL AND COBALT DETERMINATION BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BRUHN, CG ;
AMBIADO, FE ;
CID, HJ ;
WOERNER, R ;
TAPIA, J ;
GARCIA, R .
ANALYTICA CHIMICA ACTA, 1995, 306 (2-3) :183-192
[10]  
Burguera J L, 1989, PRACTICAL SPECTROSCO