Liquid chromatography-negative ion atmospheric pressure photoionization tandem mass spectrometry for the determination of brominated flame retardants in environmental water and industrial effluents

被引:38
作者
Bacaloni, Alessandro [1 ]
Callipo, Luciano [1 ]
Corradini, Eleonora [1 ]
Giansanti, Piero [1 ]
Gubbiotti, Riccardo [1 ]
Samperi, Roberto [1 ]
Lagana, Aldo [1 ]
机构
[1] Univ Roma La Sapienza, Dipartimento Chim, I-00185 Rome, Italy
关键词
Brominated flame retardants; LC-MS; Atmospheric pressure photoionization; Water analysis; Solid-phase extraction; Liquid-liquid extraction; POLYBROMINATED DIPHENYL ETHERS; SOLID-PHASE MICROEXTRACTION; GAS-CHROMATOGRAPHY; TETRABROMOBISPHENOL-A; TRACE LEVELS; HUMAN SERUM; HOUSE-DUST; EXPOSURE; SAMPLES; ELECTROSPRAY;
D O I
10.1016/j.chroma.2009.07.039
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
We describe the development of a liquid chromatography with negative-ion atmospheric pressure photoionization tandem mass spectrometric (LC/NI-APPI/MS/MS) method for the simultaneous determination of tetrabromobisphenol A (TBBP-A) and five polybrominated diphenyl ethers (BDE-47, BDE-99, BDE-100. BDE-153 and BDE-154) in water. A mobile phase methanol/acetone/water was used, where acetone acts also as dopant. NI-APPI produced precursor ions corresponding to [M-H](-) for TBBP-A, [M-Br+O](-), and [M-2Br+O](-) for the BDE congeners studied. Each compound was quantified operating in multiple reaction monitoring mode. Linearity was observed in the range 0.025-10 ng injected for all compounds. Coefficients of determination R-2 ranged from 0.9934 to 0.9982. BDEs were poorly retained by solid-phase extraction (SPE) from river water and sewage treatment plant effluent, thus liquid-liquid extraction (LLE) by n-hexane should be used for these samples. The recoveries of TBBP-A and PBDEs from tap water (SPE), river water and industrial wastewater (LLE) were in the range of 81-88%, 78-92%, and 43-99%, respectively, with relative standard deviations below 17%. The limits of detection, based on signal-to-noise ratio of 3, ranged from 0.004 to 0.1 ng injected. and method quantification limits were 0.2-3.3 ng L-1 but BDE47 (20.3 ng L-1). Only TBBP-A was found in a treated industrial sewage at 4 ng L-1, while BDE-99 and BDE-100 were detected on suspended solids. (C) 2009 Published by Elsevier B.V.
引用
收藏
页码:6400 / 6409
页数:10
相关论文
共 47 条
[1]
An overview of commercially used brominated flame retardants, their applications, their use patterns in different countries/regions and possible modes of release [J].
Alaee, M ;
Arias, P ;
Sjödin, A ;
Bergman, Å .
ENVIRONMENT INTERNATIONAL, 2003, 29 (06) :683-689
[2]
On the formation of negative ions in atmospheric pressure photoionization conditions [J].
Basso, E ;
Marotta, E ;
Seraglia, R ;
Tubaro, M ;
Traldi, P .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (10) :1113-1115
[3]
Two trace analytical methods for determination of hydroxylated PCBs and other halogenated phenolic compounds in eggs from Norwegian birds of prey [J].
Berger, U ;
Herzke, D ;
Sandanger, TM .
ANALYTICAL CHEMISTRY, 2004, 76 (02) :441-452
[4]
Brominated flame retardants: Cause for concern? [J].
Birnbaum, LS ;
Staskal, DF .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2004, 112 (01) :9-17
[5]
EVALUATION OF GRAPHITIZED CARBON-BLACK CARTRIDGES FOR RAPID ORGANIC TRACE ENRICHMENT FROM WATER - APPLICATION TO PRIORITY POLLUTANT PHENOLS [J].
BORRA, C ;
DICORCIA, A ;
MARCHETTI, M ;
SAMPERI, R .
ANALYTICAL CHEMISTRY, 1986, 58 (09) :2048-2052
[6]
BSEF Bromine Science and Environmental Forum, 2003, MAJ BROM FLAM RET VO
[7]
*BSER, 2007, EU CHEM ASS AUTH CON
[8]
Atmospheric concentrations of polybrominated diphenyl ethers at near-source sites [J].
Cahill, Thomas M. ;
Groskova, Danka ;
Charles, M. Judith ;
Sanborn, James R. ;
Denison, Michael S. ;
Baker, Lynton .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (18) :6370-6377
[9]
Comparison of analytical strategies for the chromatographic and mass spectrometric measurement of brominated flame retardants: 1. Polybrominated diphenylethers [J].
Cariou, Ronan ;
Antignac, Jean-Philippe ;
Debrauwer, Laurent ;
Maume, Daniel ;
Monteau, Fabrice ;
Zalko, Daniel ;
le Bizec, Bruno ;
Andre, Francois .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2006, 44 (08) :489-497
[10]
Liquid chromatography/tandem mass spectrometric confirmatory method for determining aflatoxin M1 in cow milk -: Comparison between electrospray and atmospheric pressure photoionization sources [J].
Cavaliere, C ;
Foglia, P ;
Pastorini, E ;
Samperi, R ;
Laganà, A .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :69-78