Electrocatalytic oxidation of glucose at a Ni-curcumin modified glassy carbon electrode

被引:81
作者
Elahi, M. Yousef
Heli, H.
Bathaie, S. Z.
Mousavi, M. F.
机构
[1] Tarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
[2] Tarbiat Modares Univ, Fac Med Sci, Dept Clin Biochem, Tehran, Iran
关键词
nickel; curcumin; glucose; modified electrode; electrocatalysis;
D O I
10.1007/s10008-006-0104-4
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The electrocatalytic oxidation of glucose was investigated on a nickel-basedchemically modified electrode (Ni(II)-curcumin) prepared by electropolymerization of Ni-curcumin complex (curcumin=1,7-bis[4-hydroxy-3-methoxyphenyl]-1,6-heptadiene-3,5-dione) in alkaline solution. Reaction kinetic and mechanism were investigated by using cyclic voltammetry (CV) and chronoamperometry (CA) techniques and steady-state polarization measurements. Cyclic voltammetry studies indicated that in the presence of glucose the anodic peak current of surface redox mediator was increased, followed by decrease in the corresponding cathodic current. This indicates that glucose was oxidized at the surface of this modified electrode. The results were explained based on the concept of electrocatalytic reactions that occur in this chemically modified electrode. The diffusion coefficient of glucose and the rate constant of the catalytic oxidation of glucose were found to be 6.7x10(-6) cm(2) s(-1) and 6.5x10(3) M-1 s(-1), respectively. It has shown that by using the Ni-curcumin modified electrode, glucose can be determined with good response and low detection limit.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 53 条
[1]   Direct determination of triamterene by potentiometry using a coated wire selective electrode [J].
Arvand, M ;
Mousavi, MF ;
Zanjanchi, MA ;
Shamsipur, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) :975-982
[2]  
Bard A.J., 2001, ELECTROCHEMICAL METH, V2nd, P236
[3]  
Bard N., 2001, ELECTROCHEMICAL METH, P209
[4]  
Becerik I, 2001, TURK J CHEM, V25, P373
[5]  
BUCHI G, 1977, J AM CHEM SOC, V99, P8073
[6]   Copper dispersed into polyaniline films as an amperometric sensor in alkaline solutions of amino acids and polyhydric compounds [J].
Casella, IG ;
Cataldi, TRI ;
Guerrieri, A ;
Desimoni, E .
ANALYTICA CHIMICA ACTA, 1996, 335 (03) :217-225
[7]   Electrochemical and XPS characterization of composite modified electrodes obtained by nickel deposition on noble metals [J].
Casella, IG ;
Gatta, M .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2969-2975
[8]   ELECTRODE MODIFICATION WITH A POLY(NI-II-TETRAMETHYLDIBENZO-TETRAAZA[14]ANNULENE) FILM - ELECTROCHEMICAL-BEHAVIOR AND REDOX CATALYSIS IN ALKALINE-SOLUTIONS .1. [J].
CATALDI, TRI ;
CENTONZE, D ;
RICCIARDI, G .
ELECTROANALYSIS, 1995, 7 (04) :312-318
[9]   Polyeugenol-modified platinum electrode for selective detection of dopamine in the presence of ascorbic acid [J].
Ciszewski, A ;
Milczarek, G .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1055-1061
[10]   Electrocatalytic properties of electropolymerized Ni(II)curcumin complex [J].
Ciszewski, A ;
Milczarek, G ;
Lewandowska, B ;
Krutowski, K .
ELECTROANALYSIS, 2003, 15 (5-6) :518-523