Electrocatalytic amperometric determination of amitrole using a cobalt-phthalocyanine-modified carbon paste electrode

被引:36
作者
Chicharro, M [1 ]
Zapardiel, A [1 ]
Bermejo, E [1 ]
Moreno, M [1 ]
Madrid, E [1 ]
机构
[1] Univ Autonoma Madrid, Fac Ciencias, Dept Quim Analit & Analisis Instrumental, E-28049 Madrid, Spain
关键词
modified carbon paste electrodes; cobalt-phthalocyanine; amitrole; aminotriazole; flow injection analysis;
D O I
10.1007/s00216-002-1345-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cobalt-phthalocyanine-modified carbon paste electrodes are shown to be excellent indicators for electrocatalytic amperometric measurements of triazolic herbicides such as amitrole, at low oxidation potentials (+0.40 V). The detection and determination of amitrole in flow injection analysis with a modified carbon paste electrode with Co-phthalocyanine is described. The concentrations of amitrole in 0.1 M NaOH solutions were determined using the electrocatalytic oxidation signal corresponding to the Co(II)/Co(III) redox process. A detection limit of 0.04 mug mL(-1) (4 ng amitrole) was obtained for a sample loop of 100 muL at a fixed potential of +0.55 V (vs. Ag/AgCl) in 0.1 M NaOH and a flow rate of 4.0 mL min(-1). Furthermore, the modified carbon paste electrodes offers reproducible responses in such a system, and the relative standard deviation was 3.3% using the same surface, 5.1% using different surface, and 6.9% using different pastes. The performance of the cobalt-phthalocyanine-modified carbon paste electrodes is illustrated here for the determination of amitrole in commercial formulations. The response of the electrodes is stable, with more than 80% of the initial retained activity after 50 min of continuous use.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 33 条
[1]   DETERMINATION OF 3-AMINO-1,2,4-TRIAZOLE (AMITROLE) IN URINE BY ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ARCHER, AW .
JOURNAL OF CHROMATOGRAPHY, 1984, 303 (01) :267-271
[2]   CHEMICALLY MODIFIED ELECTRODES IN LIQUID-CHROMATOGRAPHY DETECTION - A REVIEW [J].
BALDWIN, RP ;
THOMSEN, KN .
TALANTA, 1991, 38 (01) :1-16
[4]   HPLC WITH ELECTRODE ARRAY DETECTION - DETERMINATION OF AMITROLE IN DRINKING AND GROUND-WATER [J].
BERNWIESER, I ;
SONTAG, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (12) :499-501
[5]   Flow injection-pulse amperometric detection of ephedrine at a cobalt phthalocyanine modified carbon paste electrode [J].
Cookeas, EG ;
Efstathiou, CE .
ANALYST, 2000, 125 (06) :1147-1150
[6]   FLOW-INJECTION AMPEROMETRIC DETERMINATION OF THIOCYANATE AND SELENOCYANATE AT A COBALT PHTHALOCYANINE MODIFIED CARBON-PASTE ELECTRODE [J].
COOKEAS, EG ;
EFSTATHIOU, CE .
ANALYST, 1994, 119 (07) :1607-1612
[7]  
DOMSEIFFER JW, 1988, MED FAC LAUBOU WWET, V53, P1519
[8]   Electrochemical response of new carbon electrodes bulk modified with cobalt phthalocyanine to some thiols in the presence of heptane or human urine [J].
Filanovsky, B .
ANALYTICA CHIMICA ACTA, 1999, 394 (01) :91-100
[9]   QUANTITATIVE ESTIMATION OF 3-AMINO-1,2,4-TRIAZOLE [J].
GREEN, FO ;
FEINSTEIN, RN .
ANALYTICAL CHEMISTRY, 1957, 29 (11) :1658-1660
[10]   ELECTROCATALYTIC AND ANALYTICAL RESPONSE OF COBALT PHTHALOCYANINE CONTAINING CARBON PASTE ELECTRODES TOWARD SULFHYDRYL COMPOUNDS [J].
HALBERT, MK ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1985, 57 (03) :591-595