Predictors of psychosocial adjustment in patients with implantable cardioverter defibrillators

被引:38
作者
Burgess, ES
Quigley, JF
Moran, G
Sutton, FJ
Goodman, M
机构
[1] UNION MEM HOSP, DEPT PSYCHIAT & BEHAV MED, BALTIMORE, MD USA
[2] UNION MEM HOSP, DIV CARDIOL, BALTIMORE, MD USA
[3] LOYOLA COLL, DEPT PSYCHOL, BALTIMORE, MD 21210 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1997年 / 20卷 / 07期
关键词
implantable cardioverter defibrillator; psychological distress/adjustment; inappropriate discharges; physical activity;
D O I
10.1111/j.1540-8159.1997.tb03568.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Predictors of psychological distress/adjustment were examined in 25 patients following placement of ICDs. patients completed a demographic questionnaire and a standardized questionnaire of psychological symptoms (i.e., Symptom Checklist-90 Revised; SCL-90-R). The number of discharges categorized by thee patient as inappropriate and appropriate were also ascertained The number ICD discharges categorized as inappropriate and diminished levels of physical activity (r = 0.53 and 0.63, P < 0.01, respectively) did significantly relate to overall psychological distress. In addition, after controlling for age and prior psychiatric and physical health status through a stepwise multiple regression analysis, the occurrence of ICD discharges categorized as inappropriate and diminished physical activity continued to significantly predict overall psychological distress (R-2 = 0.41, P < 0.01). However, the number of ICD discharges categorized as appropriate did not significantly predict overall psychological distress. The results of this investigation suggest that further refinement of the ICD could reduce the risk of exposure to potential psychological distress, and an analysis of prior and anticipated patient physical activity levels should be a factor when calibrating minim um ICD discharge thresh old levels.
引用
收藏
页码:1790 / 1795
页数:6
相关论文
共 21 条
[1]  
*AG HLTH CAR POL R, 1991, RES ACT
[2]   VENTRICULAR-TACHYCARDIA AND PSYCHIATRIC DEPRESSION IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
CARNEY, RM ;
FREEDLAND, KE ;
RICH, MW ;
SMITH, LJ ;
JAFFE, AS .
AMERICAN JOURNAL OF MEDICINE, 1993, 95 (01) :23-28
[3]  
DEROGATIS LR, 1983, SCL 90 R VERSION MAN, V1
[4]  
ECHT DS, 1985, CLIN PROGR, V3, P4
[5]   DYNAMICS OF A STRESSFUL ENCOUNTER - COGNITIVE APPRAISAL, COPING, AND ENCOUNTER OUTCOMES [J].
FOLKMAN, S ;
LAZARUS, RS ;
DUNKELSCHETTER, C ;
DELONGIS, A ;
GRUEN, RJ .
JOURNAL OF PERSONALITY AND SOCIAL PSYCHOLOGY, 1986, 50 (05) :992-1003
[6]  
FRICCHIONE GL, 1986, AM J PSYCHIAT, V143, P1518
[7]   ANTIARRHYTHMIC DRUGS VERSUS IMPLANTABLE DEFIBRILLATORS - THE NEED FOR A RANDOMIZED CONTROLLED-STUDY [J].
GREENE, HL .
AMERICAN HEART JOURNAL, 1994, 127 (04) :1171-1178
[8]  
HEGEL MT, 1994, ASS ADV BEH THER CON
[9]   THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - EFFICACY, COMPLICATIONS AND SURVIVAL IN PATIENTS WITH MALIGNANT VENTRICULAR ARRHYTHMIAS [J].
KELLY, PA ;
CANNOM, DS ;
GARAN, H ;
MIRABAL, GS ;
HARTHORNE, JW ;
HURVITZ, RJ ;
VLAHAKES, GJ ;
JACOBS, ML ;
ILVENTO, JP ;
BUCKLEY, MJ ;
RUSKIN, JN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (06) :1278-1286
[10]   PATIENT ACCEPTANCE OF THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IN VENTRICULAR TACHYARRHYTHMIAS [J].
LUDERITZ, B ;
JUNG, W ;
DEISTER, A ;
MARNEROS, A ;
MANZ, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (09) :1815-1821