Comparison of two methods of assessing total body water at sea level and increasing high altitude

被引:5
作者
Boos, C. J. [1 ,2 ,3 ,4 ]
Holdsworth, D. A. [1 ,2 ]
Hall, D. P. [1 ,5 ]
Mellor, A. [1 ,6 ,7 ]
O'Hara, J. [7 ]
Woods, D. R. [1 ,8 ,9 ]
机构
[1] Dept Postgrad Med, Def Med Serv, Lichfield, Staffs, England
[2] Poole Hosp NHS Fdn Trust, Dept Cardiol, Poole BH15 2JB, Dorset, England
[3] Bournemouth Univ, Ctr Postgrad Med Res & Educ, Bournemouth, Dorset, England
[4] Royal Berkshire Hosp, Dept Cardiol, Reading RG1 5AN, Berks, England
[5] Western Gen Hosp, Dept Anaesthesia, Edinburgh EH4 2XU, Midlothian, Scotland
[6] James Cook Univ Hosp, Middlesbrough, England
[7] Leeds Metropolitan Univ, Carnegie Res Inst CRI 104, Leeds LS1 3HE, W Yorkshire, England
[8] Royal Victoria Infirm & Northumbria NHS Fdn Trust, Dept Med, Newcastle Upon Tyne, Tyne & Wear, England
[9] Newcastle Univ, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
bioimpedance analysis; BodyStat NICaS; exercise; high altitude; total body water; BIOELECTRICAL-IMPEDANCE ANALYSIS; BIOIMPEDANCE SPECTROSCOPY; CARDIAC-OUTPUT; FLUID RETENTION; HEART-FAILURE; SINGLE; COMPARTMENTS; EQUIVALENCE; INFORMATION;
D O I
10.1111/cpf.12121
中图分类号
Q4 [生理学];
学科分类号
071003 [生理学];
摘要
Fluid retention is a recognized feature of acute mountain sickness. However, accurate assessment of hydration, including the quantification of body water, has traditionally relied on expensive and non-portable equipment limiting its utility in the field setting. We compared the assessment of total body water (TBW) and their relationship to total body weight using two non-invasive methods using the NICas single-frequency bioimpedance analysis (SF-BIA) system and the BodyStat QuadScan 4000 multifrequency BIA system (MF-BIA). TBW measurements were performed at rest at sea level and at high altitude (HA) at 3833 m postexercise and at rest and thereafter at rest at 4450 m and 5129 m on 47 subjects. The average age was 34.5 +/- 9.3 years with an age range of 21-54 years (70.2% male). There were strong correlations between TBW assessment with both methods at sea level (r = 0.90; 95% CI 0.78-0.95: P< 0.0001) and at HA (r = 0.92; 0.8-0.94: P< 0.0001), however, TBW readings were 0.2 l and 1.91 l lower, respectively, with the NICaS. There was a stronger correlation between TBW and body weight with the QuadScan (r = 0.91; P< 0.0001) than with the NICaS (r = 0.83; P< 0.0001). The overall agreement between the two TBW methods was good, but the 95% confidence intervals around these agreements were relatively wide. We conclude that there was reasonable agreement between the two methods of BIA for TBW, but this agreement was lower at HA.
引用
收藏
页码:478 / 484
页数:7
相关论文
共 33 条
[1]
Assessing hydration status: the elusive gold standard [J].
Armstrong, Lawrence E. .
JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2007, 26 (05) :575S-584S
[2]
Change in body mass accurately and reliably predicts change in body water after endurance exercise [J].
Baker, Lindsay B. ;
Lang, James A. ;
Kenney, W. Larry .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2009, 105 (06) :959-967
[3]
Hypoxic Ventilatory response, ventilation, gas exchange, and fluid balance in acute mountain sickness [J].
Bärtsch, P ;
Swenson, ER ;
Paul, A ;
Jülg, B ;
Hohenhaus, E .
HIGH ALTITUDE MEDICINE & BIOLOGY, 2002, 3 (04) :361-376
[4]
BARTSCH P, 1991, AVIAT SPACE ENVIR MD, V62, P105
[5]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]
Body composition in patients with short bowel syndrome: An assessment by bioelectric impedance spectroscopy (BIS) and dual-energy absorptiometry (DXA) [J].
Carlsson, E ;
Bosaeus, I ;
Nordgren, S .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2004, 58 (06) :853-859
[7]
Effect of hypohydration and altitude exposure on aerobic exercise performance and acute mountain sickness [J].
Castellani, John W. ;
Muza, Stephen R. ;
Cheuvront, Samuel N. ;
Sils, Ingrid V. ;
Fulco, Charles S. ;
Kenefick, Robert W. ;
Beidleman, Beth A. ;
Sawka, Michael N. .
JOURNAL OF APPLIED PHYSIOLOGY, 2010, 109 (06) :1792-1800
[8]
Bioelectrical impedance and strength measurements in patients with heart failure:: comparison with functional class [J].
Castillo Martinez, Lilia ;
Colin Ramirez, Eloisa ;
Orea Tejeda, Arturo ;
Asensio Lafuente, Enrique ;
Bernal Rosales, Laura Paola ;
Rebollar Gonzalez, Veronica ;
Narvaez David, Rene ;
Dorantes Garcia, Joel .
NUTRITION, 2007, 23 (05) :412-418
[9]
Non-invasive measurement of cardiac output during coronary artery bypass grafting [J].
Cohen, AJ ;
Arnaudov, D ;
Zabeeda, D ;
Schultheis, L ;
Lashinger, J ;
Schachner, A .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 14 (01) :64-69
[10]
Accurate, noninvasive continuous monitoring of cardiac output by whole-body electrical bioimpedance [J].
Cotter, G ;
Moshkovitz, Y ;
Kaluski, E ;
Cohen, AJ ;
Miller, H ;
Goor, D ;
Vered, Z .
CHEST, 2004, 125 (04) :1431-1440