Real-time MR properties of particulate embolic agents tested in a dynamic flow model

被引:14
作者
Fidelman, N [1 ]
Wilson, MW [1 ]
Weber, OM [1 ]
Martin, AJ [1 ]
Kerlan, RK [1 ]
LaBerge, JM [1 ]
Gordon, RL [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
embolic agents; MR; flow studies;
D O I
10.1016/S1051-0443(07)61656-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Interventional magnetic resonance (MR)-guided transcatheter embolization could potentially limit radiation exposure and improve visualization of target organs. The feasibility of monitoring injection and distribution of embolic agents was assessed in a dynamic flow model with real-time MR imaging. MATERIALS AND METHODS: MR-compatible flow models were constructed with use of clear plastic chambers containing 170-mum polyethylene tubular filters. Gadolinium (Gd)-impregnated polyvinyl alcohol (PVA) particles (355-500 and 500-710 mum in size) and Gd-impregnated microspheres (Embospheres, 300-500 and 500-700 mum in size) were injected into the flow circuit under real-time dynamic T1-weighted fast field echo guidance at four images per second. A dynamic steady-state free precession sequence at four images per second was used to monitor the injection of unmodified Embo-Gold 700-900-mum particles. High-resolution scans were obtained before and after each particle injection. RESULTS: MR signal enhancement on the dynamic T1-weighted fast field echo sequence was visible during the injection of Gd-impregnated microspheres. Gd-impregnated PVA particles were not detected by this sequence. After injection, microsphere and PVA localization to the filter chambers was confirmed by the high-resolution scans. On the high-resolution sequences, relative MR signal enhancement of the microspheres was higher than that of the PVA particles. The Embo-Gold particles were minimally detectable on the dynamic sequence and undetectable by the high-resolution scan. After particle injection, direct inspection of the filter chamber showed trapping of all particle types and sizes. CONCLUSION: Real-time MR tracking of Gd-impregnated embolic agents is possible in vitro.
引用
收藏
页码:613 / 618
页数:6
相关论文
共 14 条
  • [1] BENDSZUS M, 1998, 36 ANN M AM SOC NEUR
  • [2] CORRELATION BETWEEN MAGNETIC-RESONANCE-IMAGING DISTURBANCES AND THE MAGNETIC-SUSCEPTIBILITY OF DENTAL MATERIALS
    BEUF, O
    LISSAC, M
    CREMILLIEUX, Y
    BRIGUET, A
    [J]. DENTAL MATERIALS, 1994, 10 (04) : 265 - 268
  • [3] Transcatheter uterine artery embolisation to treat large uterine fibroids
    Bradley, EA
    Reidy, JF
    Forman, RG
    Jarosz, J
    Braude, PR
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1998, 105 (02): : 235 - 240
  • [4] Plain and gadolinium-DTPA-enhanced MR imaging of hepatocellular carcinoma treated with transarterial chemoembolization
    Castrucci, M
    Sironi, S
    DeCobelli, F
    Salvioni, M
    DelMaschio, A
    [J]. ABDOMINAL IMAGING, 1996, 21 (06): : 488 - 494
  • [5] Uterine artery embolization for uterine fibroids: A radiologist's perspective
    Goodwin, SC
    Wong, GCH
    [J]. CLINICAL OBSTETRICS AND GYNECOLOGY, 2001, 44 (02) : 412 - 424
  • [6] Gadolinium-enhanced MR imaging in the evaluation of uterine fibroids treated with uterine artery embolization
    Katsumori, T
    Nakajima, I
    Tokuhiro, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (02) : 303 - 307
  • [7] Li W, 2000, J MAGN RESON IMAGING, V12, P1004, DOI 10.1002/1522-2586(200012)12:6<1004::AID-JMRI27>3.0.CO
  • [8] 2-#
  • [9] Uterine fibroid embolization: Nonsurgical treatment for symptomatic fibroids
    McLucas, B
    Adler, L
    Perrella, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2001, 192 (01) : 95 - 105
  • [10] OPPELT A, 1986, Electromedica (English Edition), V54, P15