Automated instrumentation for comprehensive isotachophoresis-capillary zone electrophoresis

被引:46
作者
Chen, SJ [1 ]
Lee, ML [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
关键词
D O I
10.1021/ac990727+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated comprehensive isotachophoresis - capillary zone electrophoresis (ITP-CZE) system is described. The sample is focused in the first capillary by ITP and injected repeatedly into the second smaller diameter capillary for more rapid CZE separation. Since only small portions of the concentrated zones are sequentially injected for CZE separation, overloading was not observed. Moreover, the sensitivity is enhanced because all of the concentrated zones are analyzed and the results are summed. A single detector (only for the CZE dimension) is required, and accurate timing for CZE injection is not necessary. The system was evaluated using a mixture of angiotensins. The effect of addition of leading electrolyte at the junction of the ITP and CZE capillaries before each CZE run on comprehensive ITP-CZE peak area was studied, and leading electrolyte volumes between 7 and 11 mu L led to the best sensitivity. Under optimized conditions, a detection limit of approximately 5 nM could be achieved by injecting 10 mu L of angiotensin solution.
引用
收藏
页码:816 / 820
页数:5
相关论文
共 23 条
[1]   SENSITIVITY ENHANCEMENT FOR CAPILLARY ELECTROPHORESIS [J].
ALBIN, M ;
GROSSMAN, PD ;
MORING, SE .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :A489-A497
[2]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[3]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :978-984
[4]  
Chen SJ, 1999, J MICROCOLUMN SEP, V11, P341, DOI 10.1002/(SICI)1520-667X(1999)11:5<341::AID-MCS3>3.0.CO
[5]  
2-#
[6]   Counterflow isotachophoresis capillary zone electrophoresis on directly coupled columns of different diameters [J].
Chen, SJ ;
Lee, ML .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3777-3780
[7]   ON-COLUMN SAMPLE CONCENTRATION USING FIELD AMPLIFICATION IN CZE [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :A489-A496
[8]   ON-COLUMN TRANSIENT AND COUPLED COLUMN ISOTACHOPHORETIC PRECONCENTRATION OF PROTEIN SAMPLES IN CAPILLARY ZONE ELECTROPHORESIS [J].
FORET, F ;
SZOKO, E ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :3-12
[9]  
Foret F, 1990, J MICROCOLUMN SEP, V2, P229
[10]   CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS [J].
HJERTEN, S ;
ELENBRING, K ;
KILAR, F ;
LIAO, JL ;
CHEN, AJC ;
SIEBERT, CJ ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :47-61