Modeling and energy simulation of the variable refrigerant flow air conditioning system with water-cooled condenser under cooling conditions

被引:55
作者
Li, Yueming [1 ]
Wu, Jingyi [1 ]
Shiochi, Sumio [2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai, Peoples R China
[2] Daikin Ind Ltd, Osaka, Japan
关键词
Energy simulation; Office building; HVAC system; Variable refrigerant flow air conditioning system with water-cooled condenser; Cooling power; HEAT-PUMP; VALIDATION; HOT;
D O I
10.1016/j.enbuild.2009.04.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As a new system, variable refrigerant flow system with water-cooled condenser (water-cooled VRF) can offer several interesting characteristics for potential users. However, at present, its dynamic simulation simultaneously in association with building and other equipments is not yet included in the energy simulation programs. Based on the EnergyPlus's codes, and using manufacturer's performance parameters and data, the special simulation module for water-cooled VRF is developed and embedded in the software of EnergyPlus. After modeling and testing the new module, on the basis of a typical office building in Shanghai with water-cooled VRF system, the monthly and seasonal cooling energy consumption and the breakdown of the total power consumption are analyzed. The simulation results show that, during the whole cooling period, the fan-coil plus fresh air (FPFA) system consumes about 20% more power than the water-cooled VRF system does. The power comparison between the water-cooled VRF system and the air-cooled VRF system is performed too. All of these can provide designers some ideas to analyze the energy features of this new system and then to determine a better scheme of the air conditioning system. (C) 2009 Published by Elsevier B.V.
引用
收藏
页码:949 / 957
页数:9
相关论文
共 24 条
[1]   Computer-aided building energy analysis techniques [J].
Al-Homoud, MS .
BUILDING AND ENVIRONMENT, 2001, 36 (04) :421-433
[2]   Evaluation of HVAC system operational strategies for commercial buildings [J].
Ardehali, MM ;
Smith, TF .
ENERGY CONVERSION AND MANAGEMENT, 1997, 38 (03) :225-236
[3]   Underground water-source loop heat-pump air-conditioning system applied in a residential building in Beijing [J].
Chen, C ;
Sun, FL ;
Feng, L ;
Liu, M .
APPLIED ENERGY, 2005, 82 (04) :331-344
[4]   Simulation of hybrid ground-coupled heat pump with domestic hot water heating systems using HVACSIM [J].
Cui, Ping ;
Yang, Hongxing ;
Spitler, Jeffrey D. ;
Fang, Zhaohong .
ENERGY AND BUILDINGS, 2008, 40 (09) :1731-1736
[5]  
*DAKIN IND LTD, 2007, DAKIN TECHN DOC VRV
[6]  
*DOE, 2002, ENERGYPLUS DOC ENG R
[7]   Development and testing of a multi-type air conditioner without using AC inverters [J].
Hu, SC ;
Yang, RH .
ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (03) :373-383
[8]   Dynamic simulation of energy management control functions for HVAC systems in buildings [J].
Huang, WZ ;
Zaheeruddin, M ;
Cho, SH .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (7-8) :926-943
[9]   Numerical simulation of a variable speed refrigeration system [J].
Koury, RNN ;
Machado, L ;
Ismail, KAR .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (02) :192-200
[10]   Analysis on energy consumption of water-loop heat pump system in China [J].
Lian, ZW ;
Park, SR ;
Qi, HN .
APPLIED THERMAL ENGINEERING, 2005, 25 (01) :73-85